Panel Mounting Dimensions - National Instruments 9154 User Manual

Reconfigurable embedded chassis with integrated mxi-express
Table of Contents

Advertisement

What to Use
NI 9154
Screwdriver, Phillips #2
NI panel mounting kit, 782818-01
Panel mounting plate
M4x22 screw (x2)
What to Do
Complete the following steps to mount the NI 9154 on a panel.
1.
Align the NI 9154 and the panel mounting plate.
2.
Fasten the panel mounting plate to the NI 9154 using the screwdriver and M4x22 screws.
NI provides these screws with the panel mounting kit. Tighten the screws to a maximum
torque of 1.3 N · m (11.5 lb · in.).
Note
because they are the correct depth and thread for the panel mounting plate.
3.
Fasten the panel mounting plate to the surface using the screwdriver and screws that are
appropriate for the surface. The maximum screw size is M5 or number 10.

Panel Mounting Dimensions

The following figure shows the panel mounting dimensions for the NI 9154.
You must use the screws provided with the NI panel mounting kit
NI 9154 User Manual | © National Instruments | 11