Away Mode

Away Mode temporarily overrides the active mode before returning the Heater back to the previously active mode.
This is useful if you are temporarily away at the shops or on holiday and want your heating to resume as normal
operation automatically when you return.
While active, Away Mode can maintain a minimum room temperature. By default, this is set to 7 °C (frost protection
temperature). This can be modifi ed before Away mode is activated. The heater will also remember the last Away
Mode Target Temperature defi ned while Away Mode is active.
The Away countdown is set in Time, a Date and a Target Temperature.
Date and Hours are set separately on the heater, making the feature useful for popping out to the shops or going
away on holiday.
• The date set is the return date; therefore, Away mode will end at 23:59 on the day before. E.g. if a return date of
02.02.2018 is set, Away mode will end at 23:59 on 01.02.2018.
• If hours are set, this will extend away mode end from 23:59 on the day before the date set.
• If only hours and no date is set, Away Mode will count from either the current time, or if a date is set.
Timer Mode
ADVANCE
User Timer
MENU
Home All Day
BACK
Out All Day
ENTER
Away
Away
ADVANCE
°
21
MENU
C
BACK
ENTER
Until
31-02-18 07:00
11
Return Date/
ADVANCE
Time
Saturday
MENU
02-2-18
BACK
07:00
ENTER
21
C
°
NOTE:
The Back button can be used to
end the Away Mode countdown
early.
Return Date/
ADVANCE
Time
MENU
BACK
ENTER
Away Set

Advertisement

Table of Contents
loading

Table of Contents