Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component or circuit for a malfunction or short.
Fuse type:
Main—F1-30 A, blade-type
Charge Circuit—F2-25 A, blade-type
1.
Remove the screws securing the control panel
to the machine.
Note:
Retain all fasteners.
2.
Lift the control pane up to access the main wiring
harness and fuse block
3.
To replace a fuse, pull out the fuse to remove
it
(Figure
39).
Figure 39
1. Main—30 A
4.
Return the control panel to its original position.
Note:
Use the screws removed previously to
secure the panel to the machine.
(Figure
39).
g014540
2. Charge circuit—25 A
Drive System
Maintenance

Checking the Tire Pressure

Service Interval: Every 25 hours—Check the tire
pressure.
Maintain the air pressure in the front and rear tires as
specified. Uneven tire pressure can cause uneven
cut. Check the pressure at the valve stem
Check the tires when they are cold to get the most
accurate pressure reading.
Refer to the maximum pressure suggested by the tire
manufacturer on the sidewall of the caster wheel tires.
Inflate the rear drive wheel tires to 90 kPa (13 psi).
1. Valve stem
40
(Figure
Figure 40
40).
g000554

Hide quick links: