6-2. Optional Auxiliary Power Receptacles

Simultaneous Welding And Auxiliary Power
Weld Current
Amperes
250
225
200
150
100
50
0
4
2
Output
120 V
Watts
Receptacle
Receptacle
Amperes
Amperes
3500
31
4260
39
5140
46
6700
60
8000
62.4
8000
62.4
8000
62.4
1
3
240 V
15.5
19
23
30
31.2
31.2
31.2
Y If unit does not have GFCI re-
ceptacles,
use
GFCI-
protected extension cord.
.
Auxiliary power decreases as
weld current increases.
Combined output of all receptacles
limited to 8 kVA/kW rating of the
generator.
GFCI Receptacle Option
1
120 V 15 A AC GFCI Recep-
tacles GFCI2 and GFCI3
GFCI2 and GFCI3 supply 60 Hz
single-phase power at weld/power
speed. Maximum output from
GFCI2 or GFCI3 is 2.4 kVA/kW. Cir-
cuit breaker protection is the same
as standard receptacles.
If a ground fault is detected, the
GFCI Reset button pops out and
the circuit opens to disconnect the
faulty
equipment.
Check
damaged tools, cords, plugs, etc.
connected to the receptacle. Press
button to reset receptacle and
resume operation.
.
At least once a month, run
engine at weld/power speed
and press Test button to verify
GFCI is working properly.
Australian Receptacle Option
2
240 V 15 A AC Australian Re-
ceptacles RC1, RC2, and
RC3
Receptacles supply 60 Hz single-
phase power at weld/power speed.
Maximum
output
from
each
receptacle is 3.6 kVA/kW.
3
Circuit Breakers CB1, CB2,
CB3
CB1, CB2, and CB3 protect RC1,
RC2, and RC3 from overload. If a
circuit breaker opens, the recep-
tacle does not work.
4
Circuit Breaker CB4
CB4 protects all the receptacles
from overload. If CB4 opens, none
of the receptacles work.
.
Press button to reset circuit
breaker. If breaker continues to
open,
contact
Factory
Authorized Service Agent.
Ref. ST-187 602-A / Ref. ST-172 782
OM-487 Page 21