  • ENGLISH, page 26
Fault
Appliance switches off
during use.
The programme does
not start.
The To-Go blade in-
sert cannot be con-
nected to the main
unit.
To-Go blender jug is
leaking.
Liquid is leaking from
the blade insert.
Cause and troubleshooting
Processing quantity is too great or processing time
was too long.
Set the rotary switch to  ⁠ .
Reduce the processing quantity.
Allow the appliance to cool down to room temperat-
ure.
The rotary switch is not set to  .
Set the rotary switch to  ⁠ .
The programme has been cancelled using the pro-
gramme button.
Set the rotary switch to  ⁠ .
1.
Press the programme button for the required pro-
2.
gramme.
Outlet protection is active.
Screw the To-Go blade insert and the To-Go
blender jug in by turning them in a clockwise direc-
tion.
a The To-Go blender jug and To-Go blade insert are
fully and tightly screwed in.
a The
and
Seal is missing from the lid.
Insert the seal.
Seal between the blender jug and the blade insert is
missing.
Insert the seal on the EasyClick blade insert.
a The seal is seated in the groove.
a The sealing lips point in the direction of the blender
jug.
a The smooth sealing surface lies against the EasyC-
lick blade insert.
markings match up.