en | Rigging-strength ratings and safety factors
4.
5.
6.
Refer to Structural rating charts, page 34 .
Figure 8.1: Left: side-to-side simplified structural-rating guidelines for EVA arrays (angle shown
exaggerated for illustration purposes). Right: front-to-back angular pull structural-rating guidelines for EVA
spreader bars
Figure 8.2: Side-to-side angular pull structural-rating guidelines for EVA spreader bars
8.5

Structural rating charts

Warning!
Use only the listed combinations.
!
2023-01 | 04 | F01U196199
The suspended column must be perpendicular (plumb) to within ±5 degrees.
If suspending a spreader bar or grid from two points, the angle between those two
suspension lines must not exceed 60° (maximum 30° from plumb each).
Never exceed 760 lb (345 kg) total column weight when using the EVA-CG coupler grid
(discontinued). When flying EVA-1151D modules (discontinued) behind EVA-2082S full-
range modules on the EVA-CG coupler grid, the maximum number of EVA-2082S full-range
modules at the front of the grid is five and the maximum number of EVA-1151D
subwoofer modules (discontinued) at the rear of the grid is three. A bottom pull-up is not
allowed when using the EVA-CG. Flying a single column from the EVA-CG is not allowed.
_
+5º
MAX
60º
MAX