Table of Contents

Advertisement

3
Use spanner to remove transit bolts.
4
Check the distance between the appliance and the wall.
More than 2cm
5
The tap connection and hose connection must be parallel.
Connecting water supply hose
• Water supply pressure must be between 100 kPa and 1000 kPa (1.0 ~ 10.0 kgf / cm
• Do not strip or crossthread when connecting Inlet hose to the valve.
• If the water supply pressure is more than 1000 kPa, a decompression device should be installed.
• Periodically check the condition of the hose and replace the hose if necessary.
Step1 : Check rubber seal inlet hose
Hose
connector
Rubber
seal
Step2 : Connect hose to water tap
Type-A : Connecting Screw-type hose to tap with thread
Type-B : Connecting Screw-type hose to tap without thread
Upper
connector
Fixing screw
Water supply
hose
Transit bolts
Unscrew
• Two rubber seals are supplied with the water inlet hoses.
• Screw the hose connector onto water supply tap.
1. Unscrew the adapter ring plate and the 4 adapter retaining screws.
Rubber
2. Push the adapter onto the end of the tap so that the rubber seal forms
packing
3. Push the water supply hose vertically upwards so that the rubber
Plate
1. Unscrew the 3 bolts with the spanner supplied.
2. Take out the 3 bolts along with the rubber bungs by slightly
twisting the bung.
Keep the transit bolts for future use.
3. Close the holes with the caps supplied.
If the distance is less than 2cm,
the water supply hose will be
kinked or folded.
They are used for preventing water leaks. Make sure the connection to
taps are sufficiently tight.
a watertight connection. Tighten the adapter ring plate and the 4
screws.
packing within in the hose can adhere completely to the tap and then
tighten it by screwing it to the right.