Fe (Overflow Error) - LG F1443KD Series Service Manual

Hide thumbs Also See for F1443KD Series:
Table of Contents

Advertisement

FE (Overflow Error)

Power off for 10sec. Then power on.
Is the water level over reference line and is the water level frequency 21.8khz?
NO
Is the water coming in
drawer continuously?
YES
Replace the
Inlet Valve
NO
Replace the
Main PCB.
assembly.
Data view type: '040'
* Water level frequency
- Press and Hold 'Prewash' & 'Temp'
simultaneously.
Drain out the water and then
Check the
Air Chamber
If FE is displayed again,
then replace the
Pressure
If FE is displayed again,
then replace the
Main
31
YES
and the
Tube
(clogged).
Switch.
PCB.