Switching the SE700 / SE500 on and off

8.2.3 Switching the SE server off

Figure
figure 32 on page 77
on/off.
The following hardware components must be switched off in the specified order.
v
1. Switch off the Application Units
Before the Application Unit is switched off, the power-on indicator lights up green.
Terminate the customer applications and the operating system properly.
Ê
The Application Unit is switched off automatically and enters standby mode.
The status indicator lights up orange. Check this before continuing.
i
Alternatively, as the administrator or AU administrator you can switch the Application
Unit off using the SE Manager (menu Hardware→ Units[ → <se server>] (SE<model>),
Units tab, Switch off symbol), see the "Operation and Administration" manual [5].
i
Further Application Units are switched off in the same way.
2. Switch off the Server Unit SU /390
As the administrator, BS2000 administrator or a privileged operator, switch off the
Ê
Server Unit using the SE Manager (menu Hardware →
Units[ → <se server>] (SE<model>), Units tab, Switch off symbol), see the "Operation and
Administration" manual [5].
When the Server Unit is switched off, the BS2000 system is shut down properly taking
into account the remaining runtime specified.
Before the Server Unit is switched off, the power-on indicator lights up green, and after
it has been switched off, it lights up orange. Check this before continuing.
80
CAUTION!
This does not disconnect the hardware components completely from the power
source (POWER STAND-BY). To cut the entire system off from the power source,
you must must disconnect the power distribution units from the power source
Notify Customer Support.
If the operating system does not automatically switch off the Application Unit,
hold the On/Off switch down for at least four seconds.
The controls, indicators and further on/off options for the AU are described in the
"Additive Components" Operating Manual [4].