Switching the server on and off
4. Switch on the optional Server Units x86
Before the Server Unit is switched on, the status indicator lights up orange.
Switch on the Server Unit by pressing the On/Off switch.
Ê
The power-on indicator lights up green. The Server Unit switches on, conducts a
system test and starts X2000.
If automatic IPL is configured for BS2000, the BS2000 system (Native or as a VM2000
monitor system) is also started with the configured settings.
If automatic startup is configured for XenVMs, these systems are also started.
i
Further Server Units x86 are switched on in the same way.
5. Switch on the optional Application Units
Before an Application Unit is switched on, the status indicator lights up orange (POWER
STAND-BY).
As the administrator or AU administrator, switch on the Application Unit using the
Ê
SE Manager (menu Hardware → Units[ → <se server>] (SE<model>), Units tab, Switch on
symbol), see the "Operation and Administration" manual [5].
Alternatively, switch on the Application Unit by pressing the On/Off switch.
The power-on indicator lights up green. The Application Unit switches on, conducts a
system test and starts the operating system.
i
Further Application Units are switched on in the same way.
U41858-J-Z126-2-76
The controls and indicators of the Server Unit are described in the "Server Unit
x86" Operating Manual [3].
The controls, indicators and further on/off options for the AU are described in the
"Additive Components" Operating Manual [4].