Frequency of Use
If your generator will be used on an infrequent or intermittent basis,
(more than 4 weeks before next use), please refer to the Battery
Service section of the SERVICING YOUR GENERATOR (see page 63)
and the Fuel section of the STORAGE chapter (see page 68) for
additional information regarding battery and fuel deterioration.

STARTING THE ENGINE

To prevent a possible fire, keep the generator at least 3 feet (1 meter)
away from building walls and other equipment during operation. Do not
place flammable objects close to the engine.
• Operating this generator less than 3 feet (1 meter) from a building or
other obstruction can cause overheating and damage the generator.
• For proper cooling, allow at least 3 feet (1 meter) of empty space
above and around the generator.
Keep all cooling holes open and clear of debris, mud, water, etc.
Cooling holes are located on the control panel and the bottom of the
generator. If the cooling holes are blocked, the generator may
overheat and damage the engine, inverter, or windings.
Refer to SAFE OPERATING PRECAUTIONS on page 28 and perform the
IS YOUR GENERATOR READY TO GO? checks (see page 26).
Refer to AC OPERATION (see page 38) for connecting loads to the
generator.
1. Make sure that all appliances
are disconnected from the AC
receptacles.
2. Set the Voltage Selector Switch
to match the voltage
requirements for the
application.
OPERATION
VOLTAGE SELECTOR SWITCH
120 V/240 V
120 V ONLY
29