15. When coolant begins to flow out of the bolt
hole, tighten the water pump air bleed bolt to
the specified torque.
Tightening torque:
Water pump air bleed bolt:
10 N·m (1.0 kgf·m, 7.4 lb·ft)
16. Remove panel E. (See page 9-10.)
17. Loosen the clamp screw, and then remove
the V-belt cooling duct.
2
1. V-belt cooling duct
2. Clamp screw
18. Loosen the cylinder head air bleed bolt, with-
out removing it, to allow all of the air to es-
cape from the air bleed bolt hole.
1
1. Cylinder head air bleed bolt
19. When coolant begins to flow out of the bolt
hole, tighten the cylinder head air bleed bolt
to the specified torque.
Tightening torque:
Cylinder head air bleed bolt:
10 N·m (1.0 kgf·m, 7.4 lb·ft)
20. Start the engine and let it idle for ten minutes.
21. Rev the engine five times.
9-35
1
9