  • Page 1 CLIMATE CONTROL COOLAIR RTX2000, SPX1200IC Parking cooler Operating manual...
  • Page 2 © 2020 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual belong to Dometic Sweden AB.
  • Page 3: Table Of Contents

    This product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit documents.dometic.com. Table of contents Explanation of symbols .
  • Page 4: Safety Instructions

    Safety instructions RTX2000, SPX1200IC NOTICE! Indicates a situation that, if not avoided, can result in property damage. NOTE Supplementary information for operating the product. Safety instructions Handling the product WARNING! • Only use the parking cooler for the purpose specified by the manufac- turer and do not make any alterations or structural changes to the device.
  • Page 5 RTX2000, SPX1200IC Safety instructions • Do not reach into air grilles or ventilation nozzles or insert any foreign objects in the system. WARNING! Keep batteries out of reach of children • The battery can cause severe or fatal injuries in 2 hours or less if it is swallowed or placed inside any part of the body.
  • Page 6: Target Group

    • Alterations to the product without express permission from the manufacturer • Use for purposes other than those described in this manual Dometic reserves the right to change product appearance and product specifications. Technical description The parking cooler can be used for conditioning inside the vehicle. The air in the inte- rior is guided into the system through the intake grille, cooled, dried and conveyed back into the interior through the blower nozzles.
  • Page 7 RTX2000, SPX1200IC Technical description In BOOST mode, the parking cooler cools the vehicle interior for not more than 20 minutes at maximum power and then switches to AUTO mode. When the set temperature is reached, the parking cooler switches to AUTO mode before the 20 minutes is reached.
  • Page 8: Operation

    Operation RTX2000, SPX1200IC Operation Device elements RTX2000 SPX1200IC The parking cooler has the following device elements: No. in Explanation fig. 1, page 8 Blower nozzles Intake grille Control panel...
  • Page 9 RTX2000, SPX1200IC Operation Control panel The system's control panel contains the following operating and display elements: No. in Symbol Description fig. 2, page 9 Display (see chapter “Display” on page 11) Infrared receiver (for the remote control) Opens the sub-menus for setting or decreases the value of the selected parameter once a menu has been opened.
  • Page 10 Operation RTX2000, SPX1200IC Remote control The remote control contains the following operating elements: No. in Symbol Description fig. 3, page 10 Press button briefly: Switches the parking cooler to standby mode or on again, if it is in standby mode Press button longer than 3 s: Switches the parking cooler off The parking cooler only can be switched on at the control...
  • Page 11 RTX2000, SPX1200IC Operation No. in Symbol Description fig. 3, page 10 Switches the parking cooler to AUTO mode. Switches the parking cooler to ECO mode. Switches the parking cooler to BOOST mode. Display The display has the following indicators: No. in Description fig.
  • Page 12: Using The Parking Cooler

    Using the parking cooler RTX2000, SPX1200IC No. in Description fig. 4, page 11 ERROR: Lights up when the supply voltage falls below a set value. Additionally the display flashes. Battery: Displays problems with the supply voltage. °C: Lights up when the temperature is shown in °C. °F: Lights up when the temperature is shown in °F.
  • Page 13 RTX2000, SPX1200IC Using the parking cooler Observe the following instructions to ensure your CoolAir parking cooler is used efficiently. It is recommended that you • Park your vehicle in the shade when possible. • Shade your vehicle when possible. • If you do not have a vehicle air conditioning system, air out your vehicle well before using the parking cooler.
  • Page 14 Using the parking cooler RTX2000, SPX1200IC ➤ With the system switched off, press the button. ✔ The fan starts. ✔ The Power LED (fig. 2 7, page 9) lights up. ✔ The digital display (fig. 2 1, page 9) shows the current status of the parking cooler (see chapter “Display”...
  • Page 15 RTX2000, SPX1200IC Using the parking cooler Using menus You can set the parking cooler to suit your requirements using the menus: ➤ Press the button to browse through the menus. ➤ Press the button to navigate to the appropriate sub-menu or to change the selected value.
  • Page 16 Using the parking cooler RTX2000, SPX1200IC Sub-menu Purpose BOOST BOOST mode: The system runs at once at full-power. The system switches to automatic mode after 20 minutes or once the set temperature has been reached. MANUAL MANUAL mode: You can set the fan speed manually. The compressor is controlled automatically.
  • Page 17 RTX2000, SPX1200IC Using the parking cooler Setting the mode Control panel ➤ Press the button until the symbol is displayed. ➤ Press the button to set the AUTO, ECO or BOOST mode. To set the MANUAL mode see below. ➤ Press the button to start the selected mode.
  • Page 18: Display Messages

    Display messages RTX2000, SPX1200IC Setting the timer The parking cooler is fitted with a timer. Once the set time has elapsed in the timer, the parking cooler automatically switches off. If the timer is activated, the display alternates between the set temperature and the duration.
  • Page 19 RTX2000, SPX1200IC Display messages Control panel warnings The system control unit has various functions for protecting the device and the battery. If one of these protective functions has been triggered, this is shown by the following codes on the display. Display Description Cause...
  • Page 20 Display messages RTX2000, SPX1200IC Display Description Cause Remedy indication ➤ Consult an authorized When operating for The system cannot mea- the first time, the sure the battery voltage. workshop and have the symbol flashes battery connection twice briefly every checked. 5 seconds: The system reports an incorrect connection...
  • Page 21 RTX2000, SPX1200IC Display messages Control panel fault messages The “ERROR” symbol (fig. 4 5, page 11) lights up if there is a fault with the parking cooler. The type of error is shown on the display by the following error codes: Display Description Cause...
  • Page 22: Cleaning And Care

    Cleaning and care RTX2000, SPX1200IC Display Description Cause Remedy text ➤ Switch off the system. The system cannot Error in temperature ➤ Switch it on again after determine the external sensor electrical supply temperature. (open circuit). 30 minutes. ➤ If the fault occurs again, Error in temperature contact an authorized sensor electrical supply...
  • Page 23: Warranty

    Warranty If the product does not work as it should, please contact your retailer or the manufacturer's branch in your country (see dometic.com/dealer). The warranty applicable to your product is 1 year(s) when used as described in the Intended use section of this manual.
  • Page 24: Disposal

    Disposal RTX2000, SPX1200IC Disposal Recycling products with batteries, rechargeable batteries and light sources ➤ Remove any batteries, rechargeable batteries, and light sources before recy- cling the product. ➤ Return defective or used batteries to your retailer or dispose of them at col- lection points.
  • Page 25 RTX2000, SPX1200IC Technical data RTX2000 12 V RTX2000 24 V Dimensions (L x W x H): 645 x 860 x 308 mm Weight: Approx. 32 kg SPX1200IC Cooling capacity: 1200 W Voltage: 24 Vg (20 Vg – 30 Vg) Current consumption: 5 –...
  • Page 28 YOUR LOCAL YOUR LOCAL YOUR LOCAL DEALER SUPPORT SALES OFFICE dometic.com/dealer dometic.com/contact dometic DOMETIC GROUP AB...