Permanently lubricated single stage portable (36 pages)
Summary of Contents for Craftsman 919.167782
Page 1
• Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D27299 Rev. 2 6/3/03...
SPECIFICATION CHART Model No. 919-167782 Bore 2.375” Stroke High Pressure - .54” Low Pressure - 1.45” Voltage-Single Phase Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity - Gallons 25 ASME Approximate Cut-in Pressure Approximate Cut-out Pressure SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand.
Page 4
IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
Page 5
HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
Page 6
HAZARD WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with it may cause electric shock.
Page 7
HAZARD WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
Page 8
HAZARD RISK OF UNSAFE OPERATION WARNING: WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
ASSEMBLY Assemble Wheels Contents of Carton It will be necessary 1 - Air Compressor to brace or support 2 - Wheels one side of the air compressor when installing the wheels because 2 - Shoulder Bolts, 3/8-16 the compressor will have a 2 - Hex Nuts, 3/8-16 tendency to tip.
INSTALLATION HOW TO SET UP YOUR This plug MUST be used with a grounded outlet. UNIT IMPORTANT: The outlet being used Location of the Air Compressor must be installed and grounded in accordance with all local codes and Locate the air compressor in a clean, ordinances.
Page 12
Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the Parts Manual for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Certain air compressors can be and overheating.
OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Tank Pressure Gauge Pressure...
Page 14
Air Compressor Pump (not shown): Motor Overload Protector: The Compresses air into the air tank. motor has an automatic reset thermal Working air is not available until the overload protector. If the motor compressor has raised the air tank overheats for any reason, the pressure above that required at the overload protector will shut off the air outlet.
Page 15
Move the On/Auto/Off lever to How to Start: "ON/AUTO" position. The Turn the On/Auto/Off lever to compressor will start. “AUTO” and allow tank pressure Run the compressor for 15 to build. Motor will stop when minutes. Make sure the drain tank pressure reaches “cut-out”...
MAINTENANCE Customer Responsibilities Daily or Before Every Every after each Yearly each hours hours Check Safety Valve Drain Tank Air Filter Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles To Check Safety Valve automatically when If the safety valve power is on.
Page 17
After the water has been drained, Air Compressor Pump Intake close the drain valve (clockwise). and Exhaust Valves The air compressor can now be Once a year have a Trained Service stored. Technician check the air compressor NOTE: If drain valve is plugged, pump intake and exhaust valves.
SERVICE AND ADJUSTMENTS Unit cycles Outlet Tube automatically when power is on. When doing Pressure Relief Maintenance, you may be exposed Check Tube to voltage sources, compressed air Valve or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
Page 19
Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section. Unplug compressor. Regulator Remove the outlet pressure gauge and quick connect (if equipped) from the regulator. Remove the regulator.
STORAGE Before you store the air compressor, Water will make sure you do the following: condense in the air tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled maintenance as necessary.
Page 21
TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
Page 22
PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the used.
Page 23
PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
Page 24
CONTENIDO GARANTÍA ............28 CUADRO DE ESPECIFICACIONES .
CUADRO DE ESPECIFICACIONES Modelo Nº 919-167782 Orificio 2.375" Carrera Presión de alto - .54" Presión de mugir - 1.45" Voltaje - Una Fase Requerimientos Mínimos de Circuito 15 Amperios Tipo de Fusible Retardo Capacidad del Tanque de Aire - Galon 25 ASME Presión de Arranque Aproximada Presión de Corte Aproximada...
Page 26
INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES LA OPERACIÓN O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRÍAN OCASIONAR SERIAS LESIONES Y DAÑOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN O INCENDIO ¿QUÉ...
Page 27
PELIGRO ADVERTENCIA: RIESGO DE EXPLOSIÓN TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRÍAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSIÓN VIOLENTA, DAÑOS A LA PROPIEDAD O SERIAS LESIONES. ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o después de en el tanque, siendo la causa del óxido cada uso.
Page 28
PELIGRO ADVERTENCIA: RIESGO DE DESCARGA ELÉCTRICA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Su compresor de aire está accionado por Jamás opere el compresor a la intemperie electricidad. Como cualquier otro dispositivo cuando está lloviendo o en condiciones de eléctrico impulsado eléctricamente, si no se lo humedad.
Page 29
PELIGRO ADVERTENCIA: RIESGO DE QUEMADURAS ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del escape, de la operación.
Page 30
PELIGRO ADVERTENCIA: RIESGO DE OPERACIÓN INSEGURA ¿QUÉ PUEDE OCURRIR? ¿CÓMO PREVENIRLO? La operacion insegura de su compresor de aire Revise y comprenda todas las instrucciones y podría ocasionarle serias lesiones o la muerte advertencias contenidas en este manual. a usted u otros. Familiarícese con los métodos de operación y control del compresor de aire.
GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
ENSAMBLADO Ensamble de las ruedas Contenido de la caja Será necesario 1- Compresor de aire soportar un lado 2- Ruedas del equipo cuando se instalan las ruedas porque el compresor tenderá a 2- Pernos con resalto, 3/8" - 16 voltearse. 2- Tuercas hexagonales, 3/8"...
INSTALACIÓN Asegúrese de que el tomacorriente que CÓMO PREPARAR LA UNIDAD será utilizado tenga la misma configuración que el enchufe de conexión Ubicación del compresor de aire a tierra. Ubique al compresor de aire en una zona NO UTILICE UN ADAPTADOR. Ver limpia, seca y bien ventilada.
Page 34
Cables de extensión eléctrica Protección del voltaje y del circuito No se recomienda la utilización de cables Acerca del voltaje y la mínima cantidad de de extensión eléctrica. El uso de cables circuitos requeridos, refiérase al Manual de extensión eléctrica originará una caída de piezas.
OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
Page 36
Bomba de compresión del aire (no automáticamente una vez enfriado el motor. mostrada): Comprime el aire dentro del Si el protector de sobrecarga apaga el tanque. El aire de trabajo no se encuentra motor con mucha frecuencia, verifique si disponible hasta que el compresor haya hay algún posible problema de voltaje.
Page 37
Cómo poner en marcha: Antes de cada puesta en marcha: Mueva la palanca On/Auto/Off a la Coloque el interruptor On/Auto/Off en la posición "AUTO" y deje que se posición "OFF" y cierre el regulador de incremente la presión del tanque. El aire.
MANTENIMIENTO Responsabilidades del cliente Antes Cada Diariamente Cada Anualmente o luego de cada horas cada uso horas Verifique la válvula de seguridad Drenaje del tanque Filtro de aire Válvulas de entrada y escape de la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
Page 39
Dentro del Si está sucio enjuague el filtro de aire tanque se con agua tibia y exprímalo hasta que producirá condensación de agua. Si no seque. drena, el agua lo corroerá y debilitará 4. Vuelva a colocar el filtro de aire y su causando un riesgo de ruptura del cubierta.
Page 40
SERVICIO Y AJUSTES La unidad cicla Tubo de Tuerca automáticamente salida en cuanto la energía eléctrica es Válvula conectada. Al efectuar el Tubo aliviador regula- mantenimiento, usted quedará de presión dora expuesto a tensión viva, aire comprimido o partes en movimiento. Debido a tales circunstancias, podrían ocurrirle lesiones personales.
Page 41
Ensamble el regulador y oriéntelo de Para reemplazar el regulador acuerdo a lo mostrado Libere toda la presión del aire del tanque. Vea "Drenaje del tanque" en la sección "Mantenimiento". Desenchufe el equipo. Regulador Usando una llave de tuercas ajustable retire el medidor de salida de presión y la conexión...
ALMACENAJE El agua se Antes de guardar su compresor de aire, condensa dentro asegúrese de hacer lo siguiente: del tanque de aire. Si no se drena, ella Revise la sección "Mantenimiento" corroerá debilitando la paredes del de las páginas precedentes y ejecute tanque de aire, originando un riesgo de el mantenimiento programado de ruptura de sus paredes.
GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
Page 44
PROBLEMA CAUSA CORRECCIÓN Si hubiese una caída excesiva de Es normal que ocurra algún La lectura de la presión durante el uso del descenso en la presión. presión sobre un accesorio, ajuste el regulador de manómetro (si acuerdo a las instrucciones de la viene equipado sección Operación.
Page 45
CAUSA PROBLEMA CORRECCIÓN El motor no Deje enfriar el motor y el El interruptor de protección des interruptor de sobrecarga se funciona. obrecarga del motor se ha reajustará automáticamente. abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
Page 48
Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.