Kenwood TK-5220 K Service Manual page 54

Table of Contents

Advertisement

TK-5220
Item
Panel tuning mode
6. Low RSSI
1) Adj item: [An LRSSI]
at –118dBm
Adjust: [✳✳✳]
adjust *7
2) Adj item:
[AnL LRSSI]→
[Analog
[AnL' LRSSI]→
Narrow]
[AnC LRSSI]→
[AnH' LRSSI]→
[AnH LRSSI]
Adjust: [✳✳✳]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [Aw LRSSI]
Wide]
Adjust: [✳✳✳]
2) Adj item:
[AwL LRSSI]→
[AwL' LRSSI]→
[AwC LRSSI]→
[AwH' LRSSI]→
[AwH LRSSI]
Adjust: [✳✳✳]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±3kHz)
*7: Because Low RSSI at –118dBm (P25 Narrow) is adjusted by adjusting Low RSSI at –118dBm (Analog Narrow), it is not necessary to adjust
Low RSSI at –118dBm (P25 Narrow).
7. High RSSI
1) Adj item: [An HRSSI]
at –80dBm
Adjust: [✳✳✳]
adjust *8
2) Adj item:
[AnL HRSSI]→
[Analog
[AnL' HRSSI]→
Narrow]
[AnC HRSSI]→
[AnH' HRSSI]→
[AnH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [Aw HRSSI]
Wide]
Adjust: [✳✳✳]
2) Adj item:
[AwL HRSSI]→
[AwL' HRSSI]→
[AwC HRSSI]→
[AwH' HRSSI]→
[AwH HRSSI]
Adjust: [✳✳✳]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
*8: Because High RSSI at –80dBm (P25 Narrow) is adjusted by adjusting High RSSI at –80dBm (Analog Narrow), it is not necessary to adjust
High RSSI at –80dBm (P25 Narrow).
54
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Low RSSI
SSG
(Analog Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [Low RSSI
(Analog Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [High RSSI
SSG
(Analog Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (Analog Wide)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–80dBm (22.4µV)
(MOD: 1kHz/±3kHz)
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Universal
connector
Panel
ANT
Universal
connector
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Remarks