Kenwood TK-5220 K Service Manual page 40

Table of Contents

Advertisement

TK-5220
Adjusutment
Order
item
22
Open Squelch
23
Low RSSI
24
High RSSI
25
Tight Squelch
26
Battery Warning Level
*1: Because P25 Narrow is adjusted by adjusting Analog Narrow, it is not necessary to adjust P25 Narrow.
■ Panel tuning mode fl ow chart
Note: In this Panel tuning mode fl ow chart, the Adjustment item name is modifi ed.
Panel test mode
[
LCD Contrast
CNTR
[
] press
[
Volume 1 (CCW Max)
VOL1
[
] press
[
Volume 2 (CW Max)
VOL2
[
] press
[
RX Assist
RAST
[
] press
[
TX Assist
TAST
[
] press
[
RTC
RTC
[
] press
[
High Power
HIPWR
[
] press
[
Low Power
LOPWR
[
] press
[
Balance
BAL
[
] press
[
P25 Deviation
PDEV
[
] press
[
40
ADJUSTMENT
Main LCD
Sub LCD display
display
(ASQDET
SQL
measurement value)
(RSSI measurement
LRSSI
value)
(RSSI measurement
HRSSI
value)
(ASQDET
SQLT
measurement value)
(BATT
BATT
measurement value)
[ ]
Adjustment Item
LCD Display
] hold
For all adjustment items, press the
[ ] key to write the adjustment value.
] hold
] hold
] hold
[
]
5 reference level
Adjustments
] hold
[
]
5 reference level
Adjustments
] hold
] hold
[
]
5 reference level
Narrow
Adjustments
] hold
[
]
5 reference level
Narrow
Adjustments
] hold
[
]
5 reference level
Narrow
Adjustments
] hold
[
]
5 reference level
Narrow
Adjustments
] hold
Aw
An
(Analog Wide)
(Analog Narrow)
Adjustment range
5
5
1~256
5
5
1~256
5
5
1~256
5
5
1~256
1 point ADJ
1~256
N/W
5 reference level
Low
Adjustments
L
Low-Center
L'
Center
C
Center-High
H'
High
H
5 reference level
Adjustments exit
Pn
Adjust item
(P25 Narrow)
Number
- *1
Receive
Section 5
- *1
Receive
Section 6
- *1
Receive
Section 7
-
Receive
Section 8
Transmitter
Section 15
[
]
Adjustment Point
LCD Display
[
]
[
]
[
]
[
]
[
]
[
]
[
]
[
]
[
]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-5220Tk-5220 k2

Table of Contents