5.3.6 Group 5* - Comfort Settings

* If Zoning is enabled, this group will be called Group 6.
MENU ITEM
Enable Dehumidification
Dehumidification Overcooling Limit - Degrees ①
Smart Continuous Fan
Control Response Rate
Aggressive Recovery ② > 2° Setpoint Change
Heating Aggressive Recovery ② by Outdoor
Temperature
Heating Aggressive Recovery ②
Setting
Warm Air Discharge ①
① This feature is not available when zoning is enabled
② Only one method of recovery can be enabled.
Refer to Section 7 Advanced Operation for additional information on each setting.
18-HD80D1-6E-EN
OPTIONS [DEFAULT] DESCRIPTION
[Enable], Disable
Select if enhanced dehumidification features are enabled.
Select the maximum amount of overcooling allowed when the
[0°] - 3°F
indoor humidity exceeds the cooling target humidity setpoint.
Enable, [Disable]
Select to enable or disable Smart Continuous Fan.
[Normal], Fast
Select the response rate of the control.
Select whether the 10-minute staging inhibit is disabled (heating or
Enable, [Disable]
cooling mode) with a setpoint change greater than 2°.
Select whether the 10-minute staging inhibit is disabled during
heating mode when the outdoor temperature falls below the
Enable, [Disable]
selected outdoor temperature (Outdoor temperature sensor must
be connected and enabled to allow this setting to be selected).
0° - 70°F [40°F]
Select the outdoor temperature for Heating Aggressive Recovery
When enabled the indoor airflow will be limited to 80% on a call
for heat pump heating. This only applies to heat pump heating with
Enable, [Disable]
no call for aux heat (An indoor unit with a variable speed blower is
required).