Husqvarna DC 655 Operator's Manual page 11

Hide thumbs Also See for DC 655:
Table of Contents

Advertisement

Available languages

Available languages

4. Start the compressor.
5. Start the fan.
To set the correct phase
If the indicator for the incorrect phase is on, there is a
phase error, and it is necessary to change the position
of the phase converter switch.
1. Disconnect the product from the power source.
2. Open the control panel.
3. Turn the phase converter switch to (A) or (B).
4. Close the control panel.
2061 - 002 - 19.04.2023
To stop the product
1. If you stop the product temporarily, stop only the fan.
2. If you stop the product for more than 1 hour, stop the
A
B
Note:
When the air compressor is on during a
short stop, the product cleans the primary filters.
WARNING:
intake when the product cleaning cycle
goes. If the air intake is not closed, dust
can come in to the air. The dust particles
are dangerous to your health.
fan, then do the steps that follow:
a) Stop the air compressor.
Always close off the air
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc 975

Table of Contents