Installation; Technical Specifications - Lincoln Electric SQUARE WAVE TIG 175 Manual

Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS - SQUARE WAVE™ TIG 175 (K1478-5)
Standard
Voltage
208/230/1/60
Duty Cycle
GTAW 25% Duty Cycle
40% Duty Cycle
60% Duty Cycle
100% Duty Cycle
SMAW 25% Duty Cycle
40% Duty Cycle
60% Duty Cycle
100% Duty Cycle
Output Current
Range
10-175 Amps
AC and DC
Wiring and Protection based on the 2008 National Electric Code.
Use a Super Lag type Fuse or Circuit Breaker with a delay in tripping action. Models with NEMA 6-50P plug
may be used with a 50 amp protected 6-50R receptacle, or with a maximum 70 amp protected 6-50R receptacle
if dedicated for the welder.
Height
Power
19.53 in.
496 mm
Source

INSTALLATION

INPUT - SINGLE PHASE ONLY
Input Current at
Rated Output
58/52 AC/DC Stick & DC TIG - 64/57 AC TIG
RATED OUTPUT
Amps
150
125
110
90
150
125
110
90
OUTPUT
Maximum Open
Circuit Voltage
(STICK AND TIG)
AC OCV: 74
DC OCV: 59
RECOMMENDED FUSE SIZES
PHYSICAL DIMENSIONS
Width
13.72 in.
349 mm
SQUARE WAVE™ TIG 175
Code
Number
11691
11826
Volts at Rated Amperes
15.0 V AC/DC
14.7 V AC/DC
14.3 V AC/DC
14.1V AC/DC
26.0 V AC/DC
25.0 V AC/DC
25.0 V AC/DC
24.0 V AC/DC
Type of Output
CC (Constant Current)
AC/DC
Depth
Weight
24.94 in.
Approx. 200 lbs.
633 mm
90.9 kgs.
A-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

1169111826

Table of Contents