Base Plate 0 986 613; Sealing Device 0 986 610 - Bosch Denoxtronic 2.1 Product Description

Test device adblue supply module
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
3.7

Base plate 0 986 613 866

The AdBlue delivery module (fig. 7, item 1) is attached
to the base plate (fig. 7, item 2).
i
Make sure that the base plate is clean.
i
Regularly lubricate the fastening threads of the base
plate so that they function smoothly.
!
Defective base plates may not be reused and must
be completely replaced.
Fig. 7:
Base plate 0 986 613 866
1 Base plate
2 AdBlue delivery module
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.
Robert Bosch GmbH
Devices and components | Denoxtronic 2.1 | 23
3.8

Sealing device 0 986 610 905

Insert the sealing device (fig. 8, item 2) into the
hole in the pressure equalization element to test the
housing of the AdBlue delivery module (fig. 8, item 1)
for leakage. The pressure equalization element must
be removed from the housing section of the AdBlue
delivery module. The clamping claw (fig. 8, item 3) of
the sealing device is required for attaching the sealing
device to the AdBlue delivery module. Use the provided
washers to set the correct distance between the
clamping claw and the sealing device. If necessary, use
additional washers (not included).
Fig. 8:
Sealing device 0 986 610 905
1 AdBlue delivery module
2 Sealing device
3 Clamping claw of the sealing device
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 2.1.
en
|
1 689 989 404
2019-03-01

Advertisement

Table of Contents
loading

Table of Contents