1.10 Electromagnetic susceptibility

The drive operates without errors when subjected to the following:
Radiated noise
Electrostatic discharge*
Magnetic field strength
* Electrostatic discharge susceptibility is measured with the drive
mounted in a representative computer system (mounted to a
ground plane with an earth ground). Discharges are applied to the
bezel or other external surfaces on the ground plane.

1.11 Reliability

Nonrecoverable read errors
Mean time between failures
Contact start-stop cycles
Preventive maintenance

1.12 Agency certification

1.12.1 Safety certification

The drives are recognized in accordance with UL 1950 and CSA C22.2
(950) and meet all applicable sections of IEC950 and EN 60950 as tested
by TUV North America.

1.12.2 Electromagnetic compatibility

Hard drives that display the CE marking comply with European Union
requirements specified in Electromagnetic Compatibility Directives.
Testing is performed to standards EN 50082-1 and EN 55022-B.
Seagate uses an independent laboratory to confirm compliance with the
EC directives specified in the previous paragraph. Drives are tested in
representative end-user systems. Although CE-marked Seagate drives
U8 Family Product Manual, Rev. A
≤ 3 volt/meter, 30 Hz to 500 MHz
≤ 10 KVolts
≤ 5 Gauss
13
1 per 10
bits read, max
500,000 power-on hours
(nominal power, 25°C ambient tem-
perature)
50,000 cycles
(at nominal voltage and temperature,
with 60 cycles per hour and a 50%
duty cycle)
None required