3-6. AUDIO SYSTEM ADJUSTMENTS
[Connection of Audio System Measuring Devices]
Connect the audio system measuring devices as shown in Fig. 5-3-17.
Recording (Camera mode)
Audio
600 Ω
oscillator
Attenuator
600 Ω: 270 Ω (1-249-410-11) + 330 Ω (1-249-411-11)
Playback (VTR mode)
Unit
AUDIO/
VIDEO
(Red)
OUT
Left
Right
TV Monitor
Video
(YELLOW)
Left (White)
Audio Level Meter or
47 kΩ
Distortion Meter
Right
47 kΩ
47 kΩ: 1-249-437-11
Fig. 5-3-17.
Unit
MIC
5–55