This section is intended to assist the operator with the initial
startup of the mixer. It is extremely important
that this section be read carefully before
attempting to use the mixer in the field.
DO NOT use your mixer until this section is
thoroughly understood.
WARNING
Failure to understand the operation of the mixer could
result in severe personal injury or damage to the mixer.
Refer to Figure 9 and Figure 10 for component locations.
CAUTION
NEVER operate the mixer in a confined
area or enclosed area structure that does
not provide an ample free flow of air.
STARTING THE MIXER (GASOLINE ENGINE)
1. Place the fuel valve lever (Figure 19) in the ON position.
OFF
Figure 19. Fuel Valve Lever (ON)
2. If starting a cold engine, place the choke lever
(Figure 20) in the CLOSED position.
CHOKE LEVER
CLOSE
Figure 20. Choke Lever (CLOSED)
PAGE 28 — EM70 SERIES PLASTER/MORTAR MIXERS • OPERATION MANUAL — REV. #2 (10/30/19)
FUEL VALVE
LEVER
ON
OPEN
3. Move the throttle lever (Figure 21) away from the slow
position, about 1/3 of the way toward the fast position.
THROTTLE
Figure 21. Throttle Lever
4. Locate the emergency stop switch (Figure 22) on the
engine cover. Pull this button outward to allow engine
starting.
EMERGENCY
STOP SWITCH
Figure 22. Emergency Stop Switch
(START Position)
5. Turn the engine switch (Figure 23) to the ON position.
ENGINE SWITCH
Figure 23. Engine ON/OFF Switch (ON)

OPERATION

LEVER
FAST SLOW
P U
T O
S H
S T
O P
PULL OUT TO
START
OFF
ON