Model No.
Cooling Capacity
ARI
Total unit watts
Cooling
Cooling
SEER (Btuh/Watts)
Ratings
Ratings
EER (Btuh/Watts)
Total Capacity
ARI Certified
ARI Certified
Total unit watts
High
High
Temperature
C.O.P (Coefficient of Performance)
Heating Ratings
Heating Ratings
HSPF
Region IV
ARI Certified
Total Capacity
Low
Lo
Total unit watts
Temperature
Temperature
Heating Ratings
C.O.P (Coefficient of Performance)
Sound Rating Number (db)
Refrigerant Charge (HCFC−22)
Blower wheel size D x W in. (mm)
Indoor Coil
Indoor Coil
Blower
Motor horsepower (W)
Net face area − sq. ft. (m
Indoor
Indoor
Tube dia. − in. (mm) & No. of rows
Coil
Coil
Fins per inch (m)
Net face area − sq. ft. (m
Outdoor
Outdoor
Tube dia. − in. (mm) & No. of rows
Coil
Coil
Fins per inch (m)
Diameter − in. (mm) & No. of blades
Air Volume − cfm (L/s)
Outdoor
Outdoor
Coil Fan
Motor horsepower (W)
Motor watts
Condensate drain size fpt − in. (mm)
No. & size of filters − in. (mm)
Net weight of basic unit − lbs. (kg)
Shipping weight of basic unit − lbs. (kg) (1 Package)
Electrical characteristics
OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA
Supplemental Electric Heat − kW range
Timed-Off Control
Thermostat Kit
Outdoor
Outdoor
Thermostat Kit
Mounting Box
High Pressure Switch
Rated in accordance with ARI Standard 210/240; 95_F (35_C) outdoor air temperature, 80_F (27_C) db / 67_F (19_C) wb entering evaporator air.
Filters are not furnished and must be ordered extra.
Model No.
Line voltage data − 60hz 1 phase
Recommended maximum fuse size or
circuit breaker size (amps)
Minimum Circuit Ampacity
Rated load amps
Compressor
Compressor
Locked rotor amps
Outdoor
Full load amps
Coil
Coil
Locked rotor amps
Fan Motor
Indoor
Full load amps
Coil
Coil
Locked rotor amps
Blower Motor
Unit power factor
Where current does not exceed 100 amps, HACR type circuit breaker may be used in place of fuse (U.S. only).
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirement
NOTE − Extremes of operating range are plus and minus 10% of line voltage.
SPECIFICATIONS 12CHP
12CHP024
Btuh (kW)
23,800 (7.0)
2160
12.00
11.00
Btuh (kW)
24,000 (7.0)
2230
3.16
7.00
Btuh (kW)
14,800 (4.3)
2100
2.06
7 lbs. 5 oz.
(3.32 kg)
10 x 7 (254 x 178)
2
)
3.6 (0.33)
5/16 (7.9) − 3
2
)
12.3 (1.14)
5/16 (7.9) − 2
18 (709)
18 (457) − 4
2300 (1085)
(1) 24 x 25 x 1
(610 x 635 x 25)
275 (125)
290 (132)
ELECTRICAL 12CHP
12CHP024
25
18.2
10.9
54
2.7
5.5
.96
12CHP030
12CHP036
28,000 (8.2)
35,000 (10.2)
2550
3210
12.00
12.00
11.00
10.90
29,400 (8.6)
35,000 (10.2)
2610
3150
3.30
3.26
7.00
7.20
17,500 (5.1)
21,800 (6.4)
2420
2960
2.12
2.16
76
7 lbs. 4 oz.
11 lbs. 0 oz.
(3.29 kg)
(4.99 kg)
10 x 8 (254 x 203)
1/2 (373)
4.2 (0.39)
14 (552)
14 (1.3)
14 (552)
1/4 (187)
250
(1) 3/4 (19)
(1) 28 x 25 x 1
(711 x 635 x 25)
310 (141)
420 (191)
325 (147)
435 (197)
208−230v, 1ph, 60hz
05,07,10
05,07,10,15
LB−29740BA (56A87)
M−1595 (31461)
12CHP030
12CHP036
208/230v
30
30
19.8
23.6
12.2
14.7
67
83
1.8
3.8
3.4
8.3
.97
.95
Page 5
12CHP042
12CHP048
42,000 (12.3)
48,000 (14.0)
3930
4510
12.00
12.00
10.70
10.65
42,000 (12.3)
48,000 (14.0)
3850
4690
3.20
3.00
7.20
7.00
25,600 (7.5)
31,000 (9.1)
3570
4330
2.10
2.10
80
10 lbs. 12 oz.
12 lbs. 3 oz.
(4.59 kg)
(5.53 kg)
10 x 10 (254 x 254)
6.1 (0.57)
3/8 (9.5) − 3
15 (591)
14.3 (1.33)
17.5 (1.63)
3/8 (9.5) − 2
12 (473)
20 (508) − 4
3000 (1415)
325
(1) 30 x 30 x 1 (762 x 762 x 25)
425 (193)
435 (197)
440 (200)
450 (204)
42K90
42K89
12CHP042
12CHP048
35
40
27.6
29.4
17.9
19.2
104
137
11
.97
.99
12CHP060
57,000 (16.7)
5230
12.00
10.90
57,000 (16.7)
5220
3.20
7.00
37,300 (10.9)
5200
2.10
10 lbs. 13 oz.
(4.90 kg)
3/4 (559)
16 (630)
455 (206)
470 (213)
10,15,20
12CHP060
50
36.7
25.0
169
3.6
7.3
1.00