Philips BJ3.1A LA Manual page 40

Table of Contents

Advertisement

EN 40
5.
BJ3.1A LA
2. Short circuit the SPI pins [2] on the SSB. They are located
outside the shielding (see figure "SPI service pads").
3. Keep the SPI pins shorted while connecting the TV to the
Mains/AC Power.
4. Release the short circuit after approx. two seconds.
5. Start up HyperTerminal (can be found in every Windows
application via Programs -> Accessories ->
Communications -> HyperTerminal). Use the following
settings:
COM1
Bits per second = 38400 (9600)*
Data bits = 8
Parity = none
Stop bits = 1
Flow control = None
6. Press "Shift U" on your PC keyboard. You should now see
the following info:
PNX2015 Loader V1.0
19-09-2003
DEVID=0x05
Erasing
MCSUM=0x0000
=
7. If you do not see the above info, restart the above
procedure, and check your HyperTerminal settings and the
connections between PC and TV.
8. Via "Transfer" -> "Send text file ...", you can send the
proper upgrade file to the TV (e.g. *.hex). This file will be
distributed via the Service Organization.
9. After successful programming, you must see the following
info (this can take several minutes!):
DCSUM=0xECB3
:Ok
MCSUM=0xECB3
Programming
PCSUM=0xECB3
Finished
10. If you do not see this info, restart the complete procedure.
11. Close HyperTerminal.
12. Disconnect and connect Mains/AC Power again.
(*) When having problems with upgrading, use the values
between brackets.
Figure 5-19 SPI service pads
Service Modes, Error Codes, and Fault Finding
2
F_15400_104.eps
110505

Advertisement

Table of Contents
loading

Table of Contents