DU AL F U EL RA N G E S
Planning Information
When installing against a combustible surface, a minimum
254 mm riser is required for a 91 cm dual fuel range with
charbroiler or griddle and all 122 cm and 152 cm models.
Follow all minimum clearances to combustible surfaces
shown in the illustration on the following page.
A Wolf pro ventilation hood is recommended with the dual
fuel range.
ELECTR ICA L
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit, servicing only this appliance
is required.
Wolf dual fuel ranges have a terminal block that allows for a
3-wire or 4-wire installation.
Performance may be compromised if the electrical supply is
less than 220 volts.
The range is supplied with a single phase and 3-phase
convertible power inlet box. The wiring diagram covering the
control circuit is provided with the oven.
REQ U IRED PO WER S UPP LY
Single phase
3phase
MAX IM UM C ON N ECTED L OAD
DU AL FUEL RA NGES
762 mm and 914 mm
1219 mm
1524 mm
|
English
6
220-240V AC, 50/60 Hz
380-415V AC, 50 Hz

SING LE PHASE

3PH ASE
19 amps
18 amps
35 amps
18 amps
38 amps
18 amps
GAS S U P P LY
Installation must conform with all applicable gas codes.
A gas supply line of 19 mm rigid pipe
provided to the range. If local codes permit, a certified, .9 m
long, 13 mm or 19 mm ID flexible appliance connector is
recommended to connect the units ISO 7/1-14 female inlet
to the gas supply line.
Wolf natural gas ranges will function up to 3124 m in
altitude without adjustment and LP gas ranges will function
up to 2621 m. If the installation exceeds these elevations,
contact an authorized Wolf dealer for a high altitude
conversion kit.
G AS RE QUI REME N TS
N ATURAL GAS
Supply Pressure
L P GAS
Supply Pressure
is advisable to
be
1 Kpa
2.75Kpa