Download Print this page
Hide thumbs Also See for dixell XRi30T:

Advertisement

Quick Links

FULL TOUCH – XRi30T AND XRi31T
SAFETY INFO
This manual is part of the product and should be kept near the instrument for easy and quick reference.
The instrument shall not be used for purposes different from those described hereunder. It cannot be used as a safety device.
Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring the same and unchanged functionality.
In case of failure or faulty operation contact the local distributor or "Dixell S.r.l." with a detailed description of the fault.
The instrument must not be opened.
Check the application limits and the correct power supply voltage before proceeding.
Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high
atmospheric humidity to avoid condensation
Warning: disconnect the power supply and all other electrical connections before any kind of maintenance.
Observe the maximum current value which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
USER INTERFACE
SCREEN
APPEARANCE
Home
Virtual
Keyboard
Parameter
Menu
1569005020 XRi30-31T QRG EN v1.2 2020.08.26
Please put this label near the controller in order to keep
all information you need at your fingertips!
CONTACT:
dixell.service@emerson.com
SCREEN
APPEARANCE
Info
Programming
Mode
Set Point Menu
SCREEN NAME
This screen shows temperature value, measurement unit and active alarms only. This is the first screen after power
Home
on or after exit from other status.
Virtual Keyboard
This screen shows available functions. Activated function will blink when this screen is visualized.
Info
This screen shows activated functions and regulation outputs (compressor, ventilators)
Programming Mode This screen enables the modification of Set point or parameters.
Parameter Menu
These screens enable the modification of all parameter values.
Set Point Menu
This screen enables the modification of the Set Point value.
USER INTERACTION
HOME NAVIGATION
PROG MENU ACTIVATION
H-SWIPE
H-SWIPE
GESTURE
HOW-TO
Press a specific area of the
ONE TAP
surface with a finger for 1 sec
TAP and
Press anyplace of the surface with
HOLD
a finger for 3 sec
Drag a finger across surface, from
H-SWIPE
left to right or from right to left
Drag a finger across surface, from
V-SWIPE
top to bottom or from bottom to top
(overlapping only one of the digits)
XRi30T - XRi31T
DESCRIPTION
SET POINT MODIFICATION
TAP and HOLD on SET
TAP and HOLD
DESCRIPTION
Switch ON / Switch OFF: when in Virtual Keyboard, use this to turn on/off a specific
function. When into programming mode, use this to select a parameter or a
parameter value.
Enter / Save: use this to enter programming mode or parameter menu and to save
modifications. When in Virtual Keyboard, use this on the "ONOFF" to switch OFF
and ON the device.
Browse: use horizontal swipe (right to left or left to right) to browse through HOME,
Virtual Keyboard and Info View. When in Programming menu: use horizontal swipe
to browse through parameter menu.
Modify: use vertical swipe (from top to bottom or bottom to top) to change a
parameter value.
PROG MENU NAVIGATION
TAP and HOLD on PRG
1/2

Advertisement

loading

Summary of Contents for Emerson dixell XRi30T

  • Page 1 H-SWIPE TAP and HOLD on SET TAP and HOLD TAP and HOLD on PRG CONTACT: dixell.service@emerson.com SAFETY INFO • This manual is part of the product and should be kept near the instrument for easy and quick reference. • The instrument shall not be used for purposes different from those described hereunder. It cannot be used as a safety device.
  • Page 2 FEATURES DESCRIPTION PROGRAMMING MENU Rated Impulse Voltage 2500V Display White display, LED type, 3 digits with decimal point and multi-function icons Buzzer Internal, always present Software Class Terminal blocks / Terminal Plug-in or screw terminal block, wire section between 0,5 and 2,5 mm2 TAP and HOLD Connections Max tightening force: 0.3 N/m for 3,5mm pitch, 0.4 N/m for 5,0mm pitch...

This manual is also suitable for:

Dixell xri31t