8. If there are no drawers placed immediately above the system, install drawer anti-tip
guides as shown in the rack drawer rail instructions shipped with the system. This
will help support the drawers when placed in their rear service position.
CAUTION:
The stabilizer must be firmly attached to the bottom front of the rack to prevent
the rack from turning over when the drawers are pulled out of the rack. Do not
pull out or install any drawer or feature if the stabilizer is not attached to the
rack.
CAUTION:
The stabilizer must be firmly attached to the bottom rear of the rack to prevent
the rack from turning over when the drawers are pulled out of the rack. Do not
pull out or install any drawer or feature if the stabilizer is not attached to the
rack.
To set up the rails in the rack, do the following:
1. Determine the EIA locations for the drawer rails. (See "Step 5. Setting Up Rails in
the Rack" on page 5.)
2. Install the nut clip on the rails, install the rails in the rack unit as shown in the
following figure.
R
Primary
I/O Drawer
(5 EIA Units)
CEC Drawer
(5 EIA Units)
Chapter 1. Setting Up the System
7