1. DSP and CPU Check
The DSP and CPU check is carried out automatically. The CHECK LED
lights up green if no problem occurs and flashes red in the event of a
defect.
* If the LED flashes red, operation stops and execution cannot advance to the next
test item. Possible causes include a fault in the peripheral circuitry for the DSP
or CPU, or a soldering defect. Detach the AC adaptor to switch off the power to
the unit.
If the CHECK LED lights up green, follow the procedure below to carry
out a DSP throughput check.
1.
Connect the oscilloscope to the OUTPUT A and B jacks.
2.
Connect the signal generator to the GUITAR IN jack and input a signal
like the following.
200-Hz rectangular wave at 1 Vp-p
3.
Verify that a signal like the following (the same as the input signal) is
output from OUTPUT A and B.
200-Hz rectangular wave at 1 Vp-p
fig.001.eps
500 mV/div. and 1 ms/div
2. Volume Check
Verify that the MODE control is set to MOMENTARY.
* The volume check can be executed only in this sequence: RES -> MANUAL ->
DEPTH -> RATE -> MODE.
RES Volume Check
Slowly turn the RES control from MIN to center, and then to MAX, and
verify that the CHECK LED changes in this sequence: green -> orange ->
green -> orange -> green.
MANUAL Volume Check
Slowly turn the MANUAL control from MIN to center, and then to MAX,
and verify that the CHECK LED changes in this sequence: green ->
orange -> green -> orange -> green.
DEPTH Volume Check
Slowly turn the DEPTH control from MIN to center, and then to MAX,
and verify that the CHECK LED changes in this sequence: green ->
orange -> green -> orange -> green.
RATE Volume Check
Slowly turn the RATE control from MIN to center, and then to MAX, and
verify that the CHECK LED changes in this sequence: green -> orange ->
green -> orange -> green.
MODE Volume Check
Turn the MODE control clockwise by one click at a time, and verify that
the CHECK LED changes in this sequence: green (MOMENTARY) ->
orange (GATE/PAN) -> red (STANDARD) -> green (ULTRA).
10
3. CODEC (DAC) Check
1.
Set the MODE control to GATE/PAN.
2.
Verify that the CHECK LED is lighted up orange.
3.
Connect the oscilloscope to the OUTPUT A and B jacks.
4.
Connect a plug to the GUITAR IN jack.
* A waveform is output even when no signal is input.
5.
Verify that a signal like the following is output from OUTPUT A and B.
200-Hz rectangular wave at 1 Vp-p
fig.002.eps
500 mV/div. and 1 ms/div.
6.
Disconnect the plug from the GUITAR IN jack and connect it to the BASS
IN jack.
7.
Verify that a signal like the following is output from OUTPUT A and B.
400-Hz rectangular wave at 1 Vp-p
fig.003.eps
500 mV/div. and 1 ms/div.
8.
Disconnect the plug from the OUTPUT B jack.
9.
Verify that a signal like the following (delta wave) is output from
OUTPUT A.
fig.004.eps
500 mV/div. and 1 ms/div.
BF-3(T)