Mitsubishi Electric MSZ-AY25VGKP Operating Instructions Manual

Mitsubishi Electric MSZ-AY25VGKP Operating Instructions Manual

Hide thumbs Also See for MSZ-AY25VGKP:

Advertisement

SPLIT-TYPE AIR CONDITIONERS
INDOOR UNIT
MSZ-AY25VGKP MSZ-AY35VGKP MSZ-AY42VGKP MSZ-AY50VGKP
MSZ-AY25VGK
MSZ-AY35VGK
MSZ-AY42VGK
MSZ-AY50VGK
OPERATING INSTRUCTIONS
BEDIENUNGSANLEITUNG
NOTICE D'UTILISATION
BEDIENINGSINSTRUCTIES
MANUAL DE INSTRUCCIONES
LIBRETTO D'ISTRUZIONI
ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ
INSTRUÇÕES DE OPERAÇÃO
РЪКОВОДСТВО ЗА ЕКСПЛОАТАЦИЯ
INSTRUKCJA OBSŁUGI
NÁVOD K OBSLUZE
NÁVOD NA OBSLUHU
HASZNÁLATI ÚTMUTATÓ
NAVODILA ZA UPORABO
INSTRUCŢIUNI DE UTILIZARE
UPUTE ZA UPORABU
UPUTSTVA ZA RUKOVANJE
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
Português
Български
Polski
Čeština
Slovenčina
Magyar
Slovenščina
Română
Hrvatski
Srpski

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MSZ-AY25VGKP

  • Page 1 SPLIT-TYPE AIR CONDITIONERS INDOOR UNIT MSZ-AY25VGKP MSZ-AY35VGKP MSZ-AY42VGKP MSZ-AY50VGKP MSZ-AY25VGK MSZ-AY35VGK MSZ-AY42VGK MSZ-AY50VGK English OPERATING INSTRUCTIONS Deutsch BEDIENUNGSANLEITUNG Français NOTICE D’UTILISATION Nederlands BEDIENINGSINSTRUCTIES Español MANUAL DE INSTRUCCIONES Italiano LIBRETTO D’ISTRUZIONI Ελληνικά ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ Português INSTRUÇÕES DE OPERAÇÃO Български РЪКОВОДСТВО ЗА ЕКСПЛОАТАЦИЯ...
  • Page 2 ● OPERATING INSTRUCTIONS ● ENGLISH IS ORIGINAL ONTENTS I SAFETY PRECAUTIONS I DISPOSAL I NAME OF EACH PART I PREPARATION BEFORE OPERATION I SELECTING OPERATION MODES I FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT I I-SAVE OPERATION I ECONO COOL OPERATION I NIGHT MODE OPERATION I AIR PURIFYING OPERATION I TIMER OPERATION (ON/OFF TIMER)
  • Page 3: Safety Precautions

    To use this unit correctly and safely, be sure to read these operating instructions before use. AFETY PRECAUTIONS The unit should not be installed, relocated, disassembled, altered, Do not pull the power cord. or repaired by the user. • This may cause a portion of the core wire to break, which may cause •...
  • Page 4 It can cause malfunctions. ISPOSAL To dispose of this product, consult your dealer. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and...
  • Page 5 AME OF EACH PART Indoor unit Remote controller Battery replacement indicator Signal transmitting Page 5 Air purifying device Front panel section (VGKP type only) Distance of signal : Operation dis- Air inlet About 6 m play section Wi-Fi interface ® Beep(s) is (are) heard from Page 14 the indoor unit when the...
  • Page 6: Preparation Before Operation

    ● OPERATING INSTRUCTIONS ● REPARATION BEFORE OPERATION Setting current time Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on. Installing the remote controller batteries Press the DAY button to set the day. Press RESET. Press CLOCK.
  • Page 7: Selecting Operation Modes

    ELECTING OPERATION MODES DRY mode Dehumidify your room. The room may be cooled slightly. Temperature cannot be set during DRY mode. HEAT mode Enjoy warm air at your desired temperature. FAN mode Circulate the air in your room. Note: After COOL/DRY mode operation, it is recommended to operate in the FAN mode to dry inside the indoor unit.
  • Page 8 ● OPERATING INSTRUCTIONS ● AN SPEED AND AIRFLOW DIRECTION ADJUSTMENT Up-down Airflow direction Press to select airfl ow direction. Each press changes airfl ow direction in the following order: (AUTO) (SWING) (AUTO) ..The vane is set to the most effi cient airfl ow direction. COOL/ DRY/FAN: horizontal position.
  • Page 9: Save Operation

    -SAVE OPERATION CONO COOL OPERATION A simplifi ed set back function enables to recall the preferred (preset) Swing airfl ow (change of airfl ow) makes you feel cooler than station- setting with a single push of the button. Press the button again ary airfl...
  • Page 10 ● OPERATING INSTRUCTIONS ● IGHT MODE OPERATION IR PURIFYING OPERATION <VGKP type only> NIGHT MODE operation changes the brightness of the operation indicator, disables the beep sound and limits the noise level of the In the AIR PURIFYING operation, the indoor unit built-in device reduces outdoor unit.
  • Page 11 IMER OPERATION (ON/OFF TIMER) Press during operation to set the timer. (ON timer) : The unit turns ON at the set time. (OFF timer) : The unit turns OFF at the set time. blinks. * Make sure that the current time and day are set correctly. Page 5 Press (forward) and...
  • Page 12: Weekly Timer Operation

    ● OPERATING INSTRUCTIONS ● EEKLY TIMER OPERATION • A maximum of 4 ON or OFF timers can be set for individual days of the week. • A maximum of 28 ON or OFF timers can be set for a week. Press , and to set ON/OFF, time, and...
  • Page 13: Emergency Operation

    MERGENCY OPERATION ELF CLEAN OPERATION When the remote controller cannot be used... Emergency operation can be activated by pressing the emergency operation switch (E.O. SW) on the indoor unit. Each time the E.O. SW is pressed, the operation changes in the following order: Operation indicator lamp Emergency COOL...
  • Page 14 ● OPERATING INSTRUCTIONS ● LEANING Instructions: • Switch off the power supply or turn off the breaker before cleaning. • Do not use a scrubbing brush, a hard sponge, or the like. • Be careful not to touch the metal parts with your hands. •...
  • Page 15 : XXXXXXXXXXXX : XXXXXXXXXXXX VOLTAGE Connect the Router to the air conditioner. CURRENT MITSUBISHI ELECTRIC CORPRATION MODE UNIT Make sure that the LED indication is as shown below. Push WPS button of the Router within 2 minutes after the mode selec-...
  • Page 16 ● OPERATING INSTRUCTIONS ● i-Fi INTERFACE SETTING UP ® Setting up in Access Point mode Register the information of the Router on the air condi- tioner. Complete the setting up in the Access Point mode within 10 minutes. In the displayed window, select Dynamic in DHCP (*1) Access Point mode and enter the information of Router, then tap the Sub- To enter the mode...
  • Page 17 ® • Make sure that DHCP is enabled, or check IP address setting of the Wi-Fi ® Mitsubishi Electric is not responsible for any (i) underperformance of a interface. system or any product; • Check DNS settings of the Router, or check DNS address of the Wi-Fi inter- ®...
  • Page 18: When You Think That Trouble Has Occurred

    ● OPERATING INSTRUCTIONS ● HEN YOU THINK THAT TROUBLE HAS OCCURRED Symptom Explanation & Check points Even if these items are checked, when the unit does not recover from the Outdoor Unit trouble, stop using the air conditioner and consult your dealer. White smoke is discharged from •...
  • Page 19 HEN YOU THINK THAT TROUBLE HAS OCCURRED In the following cases, stop using the air conditioner and consult your dealer. • When water leaks or drips from the indoor unit. • When the operation indicator lamp blinks. • When the breaker trips frequently. •...
  • Page 20 ● OPERATING INSTRUCTIONS ● HEN THE AIR CONDITIONER IS NOT NSTALLATION PLACE AND GOING TO BE USED FOR A LONG TIME ELECTRICAL WORK Installation place Operate by COOL mode with the highest temperature Avoid installing the air conditioner in the following places. set or FAN mode for 3 to 4 hours.
  • Page 21: Specifications

    PECIFICATIONS Indoor MSZ-AY25VGK(P) MSZ-AY35VGK(P) MSZ-AY42VGK(P) MSZ-AY50VGK(P) Model Outdoor MUZ-AY25VG(H) MUZ-AY35VG(H) MUZ-AY42VG(H) MUZ-AY50VG(H) Function Cooling Heating Cooling Heating Cooling Heating Cooling Heating Power supply ~ /N, 230 V, 50 Hz Capacity Input 0.60 0.78 0.99 1.03 1.30 1.39 1.54 1.47 Indoor VGKP: 11, VGK: 10.5 Weight Outdoor...
  • Page 22 Hammarbacken 14, P.O. Box 750, SE-19127, Sollentuna, Sweden UK Branch Travellers Lane, Hatfield, Hertfordshire, AL10 8XB. England, UK Polish Branch Krakowska 48, PL-32-083 Balice, Poland MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A.Ş Şerifali Mahallesi Kale Sokak No: 41 34775 Ümraniye, İstanbul, Turkey...
  • Page 23 UK DECLARATION OF CONFORMITY MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS MANUFACTURING TURKEY JOINT STOCK COMPANY. Manisa OSB 4.Kisim Kecilikoyosb Mah. Ahmet Nazif Zorlu Bulvari No:19 Yunusemre - Manisa. hereby declares under its sole responsibility that the air conditioner(s) and heat pump(s) for use in residential, commercial, and light-industrial environments described below:...
  • Page 24 EÚ VYHLÁSENIE O ZHODE EU-OVERENSSTEMMELSESERKLÆRING EU MEGFELELŐSÉGI NYILATKOZAT MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS MANUFACTURING TURKEY JOINT STOCK COMPANY. Manisa OSB 4.Kisim Kecilikoyosb Mah. Ahmet Nazif Zorlu Bulvari No:19 Yunusemre - Manisa. hereby declares under its sole responsibility that the air conditioner(s) and heat pump(s) for use in residential, commercial, and light-industrial environments described below: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlage(n) und Wärmepumpe(n) für das häusliche, kommerzielle und leichtindustrielle Umfeld wie unten beschrieben:...

Table of Contents