Start-Up - Lennox 80G2UH-V Installation Instructions Manual

Warm air gas furnace upflow/horizontal left/right air discharge
Table of Contents

Advertisement

Model
80G2UH070AV12
80G2UH090BV16
80G2UH110CV20

Start-Up

For Your Safety, Read Before Operating
Do not use this furnace if any part has been under
water. Immediately call a licensed professional service
technician (or equivalent) to inspect the furnace and
to replace any part of the control system and any gas
control which has been under water.
If overheating occurs or if gas supply fails to shut off,
shut off the manual gas valve to the appliance before
shutting off electrical supply.
Before
attempting
to
maintenance, turn the electrical power to unit OFF at
disconnect switch.
507335-03
Speed Adjust
Setting "D"
+10%
Allowed
Norm
Allowed
-10%
Allowed
+10%
Allowed
Norm
Allowed
-10%
Allowed
+10%
Allowed
Norm
Allowed
-10%
Allowed
Allowable Circulation Speeds
Model
All Models
WARNING
WARNING
CAUTION
perform
any
service
Allowable Heating Speeds
Setting "C"
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Allowed
Table 11.
38% of Second Stage Cooling
Factory Setting
Table 12.
During blower operation, the ECM motor emits
energy that may interfere with pacemaker operation.
Interference is reduced by both the sheet metal cabinet
and distance.
BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
The gas valve on this unit is equipped with a gas control
switch. Use only your hand to move the switch. Never use
tools. If the switch will not turn or if the control switch will
not move by hand, do not try to repair it.
Placing the Furnace into Operation
These units are equipped with an automatic ignition
system. Do not attempt to manually light burners on these
furnaces. Each time the thermostat calls for heat, the
burners will automatically light. The ignitor does not get hot
when there is no call for heat on units with an automatic
ignition system.
or
If you do not follow these instructions exactly, a fire
or explosion may result causing property damage,
personal injury, or loss of life.
Issue 2302
Setting "B"
Setting "A"
Allowed
Not Allowed
Factory Setting
Allowed
Allowed
Allowed
Allowed
Not Allowed
Factory Setting
Not Allowed
Allowed
Allowed
Allowed
Not Allowed
Factory Setting
Allowed
Allowed
Allowed
WARNING
WARNING
Page 29 of 39

Advertisement

Table of Contents
loading

Table of Contents