Standby Timer Timeout Period; Sleep Command (99 H , E6 H ) - Seagate Medalist 1270 Product Manual

Ata interface drive
Hide thumbs Also See for Medalist 1270:
Table of Contents

Advertisement

Medalist 1270 Product Manual, August 1995
If the drive receives a Set Features command with a mechanism and
mode value of 0000 0001 and the drive supports disabling of IORDY,
then the drive sets its default PIO transfer mode and disables IORDY.

3.2.3 Standby timer timeout period

The Idle command and Standby command Sector Count registers are
used to activate the Standby timer. The host can enable the Standby
timer by placing a value in the sector-count register of the Idle command
or Standby command. The value corresponds to a predetermined period
of drive inactivity. The table below lists the values the Seagate drive uses
and their corresponding timeout period.
Sector Count Register contents Corresponding timeout period
0 (0
)
H
1–12 (1
–C
)
H
H
13–240 (D
–F0
)
H
H
241–251 (F1
–FB
)
H
H
252 (FC
)
H
253 (FD
)
H
254 (FE
)
H
255 (FF
)
H
The drive is shipped with the Standby timer disabled.
3.2.4 Sleep command (99
This command performs the same function as the Standby Immediate
command (94
, E0
).
H
H
Timeout disabled
value = 60 seconds
(value * 5) seconds
(value – 240) * 30) minutes
21 minutes
8 hours
Reserved
21 minutes 15 seconds
, E6
)
H
H
33

Advertisement