22

2.4.3 Remote LED

You can connect a remote LED to pins 13 (−) and 14 (+) of the options
jumper block (J8). The LED is polarized and can be damaged if it is
installed incorrectly.
Because the jumper block uses a 0.1-inch connector, you may need to
replace the current connector. Use Seagate connector part number
10562-001 or an equivalent.

2.4.4 Cable-select

Computers that use cable-select determine the master and slave drives
by selecting or deselecting pin 28, CSEL, on the interface bus. Master
and slave drives are determined by their physical position on the bus.
• The drive plugged into the I/O connector that carries the CSEL signal
is the master.
• The drive plugged into the I/O connector that does not carry the CSEL
signal is the slave.
To configure the drive for computers using cable select:
• Install jumpers on pins 1 and 2 and pins 3 and 4 as shown in Figure
4 on page 21.
• Connect the drive to the bus as shown in Figure 5.
CSEL not carried
to pin 28 of
this connector

Figure 5. Connecting cable-selected drives

Medalist 1270 Product Manual, August 1995
Slave
Master
Pin 28 grounded