Download Print this page
Crestron FlipTop FT2 Series Quick Start Manual

Crestron FlipTop FT2 Series Quick Start Manual

Cable management system, 1400 size, mechanical, pass-through lid
Hide thumbs Also See for FlipTop FT2 Series:

Advertisement

Quick Links

FT2-1400-MECH-PTL
FlipTop™ FT2 Series Cable Management System, 1400 Size, Mechanical, Pass-Through Lid
The Crestron®
FT2-1400-MECH-PTL
system installs into a table or other horizontal surface to provide
modular connectivity. It features two lids that retract separately and
disappear within the enclosure. Holding 18 module slots in total, each
FT2-1400-MECH-PTL lid protects a row of nine module slots. The flexible
modular design may also be customized with an assortment of Crestron
accessories, and the pass-through lid style allows cables to be fully
extended while the lids are closed.
For more information about the accessories, please visit
www.crestron.com/Crestron-FlipTops. To configure your FlipTop, launch
the
FlipTop Configuration
Tool.
In the Box
FT2-1400-MECH-PTL
1
Additional Items
4
Locking Bars with screws and gaskets (4532619)
Cutout Template (4527605)
1
FlipTop™ cable management
Quick Start
1

Advertisement

loading

Summary of Contents for Crestron FlipTop FT2 Series

  • Page 1 Holding 18 module slots in total, each FT2-1400-MECH-PTL lid protects a row of nine module slots. The flexible modular design may also be customized with an assortment of Crestron accessories, and the pass-through lid style allows cables to be fully extended while the lids are closed.
  • Page 2 Quick Start FT2-1400-MECH-PTL FlipTop™ FT2 Series Cable Management System, 1400 Size, Mechanical, Pass-Through Lid Secure the FlipTop Assembly Mount the FlipTop Assembly To secure the FT2-1400-MECH-PTL to the table surface: 1. Gently remove the bezel before securing the FT2 assembly to the A mounting hole is required for an FT2-1400-MECH-PTL installation.
  • Page 3: Install The Modules

    Choose the appropriate slot based on the length of the cable www.crestron.com/manuals. connector. The top of the connector must sit flush with the top of the The following sections provide best practices and installation procedures module.
  • Page 4 Quick Start FT2-1400-MECH-PTL FlipTop™ FT2 Series Cable Management System, 1400 Size, Mechanical, Pass-Through Lid 3. Attach the side plate to the module by snapping the plastic clips on 5. Insert the cable plate into one of the three slots in the pass-through the plate into the two slots on the module.
  • Page 5 Quick Start FT2-1400-MECH-PTL FlipTop™ FT2 Series Cable Management System, 1400 Size, Mechanical, Pass-Through Lid Install the Blank and Keystone Plate Module 6. Attach the side plate to the module by snapping the plastic clips on the plate into the two slots on the module. Blank plate modules (sold separately) fill empty slots in module rows, and keystone plate modules (sold separately) allow for cables NOTE:...
  • Page 6: Install The Bezel

    Quick Start FT2-1400-MECH-PTL FlipTop™ FT2 Series Cable Management System, 1400 Size, Mechanical, Pass-Through Lid Install the Locking Bars Install the Bezel To install the locking bars: Place the bezel onto the FT2 assembly so that the retractable lid fits inside the bezel opening. The bezel is held in place using magnets. 1.
  • Page 7 Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.

This manual is also suitable for:

Fliptop ft2-1400-mech-ptl