Figure 19. LEDs on the Firmware and RoT Security Module
AP0 LED (Green)
1
Table 26. LEDs description
Scenario
RoT security module fatal
firmware failure
No system power (FPGA
heartbeat LED off)
XCC firmware recoverable
error
XCC firmware is recovered
from error
UEFI firmware authentication
failure
AP1 LED (Green)
2
Fatal
AP0
AP1
Error
LED
LED
LED
Off
Off
On
Blink
N/A
On
Blink
N/A
On
Off
Off
Off
Blink
N/A
Off
Blink
N/A
Off
N/A
Blink
Off
Fatal Error LED (Amber)
3
FPGA
XCC
heart-
heart-
beat
beat
note
note
LED
LED
Actions
N/A
N/A
Replace the Firmware and
RoT Security Module.
N/A
N/A
Replace the Firmware and
RoT Security Module.
On
N/A
Replace the Firmware and
RoT Security Module.
Off
Off
If the AC power is on, but the
system board assembly does
not have power, then:
1. Check the power supply
2. If the PSU or PIB is good,
N/A
N/A
Information only. No action is
required.
N/A
N/A
Information only. No action is
required.
N/A
N/A
Information only. No action is
required.
Chapter 2
unit (PSU) or power
interposer board (PIB) if
any. If the PSU or PIB has
any error, replace it.
do the following:
a. Replace the system I/
O board.
b. Replace the processor
board.
.
Server components
55