This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0100
User Action:
Make sure power cables are connected correctly.
• FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0104
User Action:
Please check wattage consistency of PSU on XClarity Controller (XCC) Web GUI. If the PSUs are not of
the same wattage, replace one to make the wattage of two PSUs consistenet, and make sure the wattage
is supported by the system.
• FQXSPPW0008I: [SensorElementName] has been turned off.
This message is for the use case when an implementation has detected a Power Unit that has been
Disabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Power Off
SNMP Trap ID: 23
CIM Prefix: PLAT CIM ID: 0106
User Action:
Information only; no action is required
• FQXSPPW0009I: [PowerSupplyElementName] has been Power Cycled.
This message is for the use case when an implementation has detected a Power Unit that has been power
cycled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0108
User Action:
.
Chapter 2