Wiring
Figure 2: Wiring
Wiring description
12 VDC
Red
GND
Black
A
Pink
B
Violet
Tamp
Blue
Tamp
Green
LG-
Yellow
LR-
Orange
D1
White
D0
Green
Connecting Biometric readers to controllers
Figure 3: Wiring instructions
•
Connect the lines D0, D1, LR-, LG-, GND and +12V to the
TruPortal controller.
•
Connect the RS485 Line (A, B) to the converter. Connect
the converter in the PC.
•
Fingerprint enrollment is done from the ACL800
BioManager software. Connection between the biometric
readers and the PC must be established.
•
The Biometric readers communicate with each other with
a RS485 and with the ACL800 BioManager software through a
converter.
2 / 7
+12 VDC
Ground
A (RS485)
B (RS485)
Tamper
Tamper
LED green -
LED red -
Data 1
Data 0
•
The RS485 Line should be configured in the form of a
daisy chain, NOT in a form of a star. Keep the stubs from the
RS485 backbone as short as possible (not more than 5
meters)
•
Only one converter per installation is needed, not per
reader.
RS485 tuning
Figure 4: RS485 tuning
•
Terminate both ends of the line with 120 Ohm resistor
•
If the communication is not established and stable, use the
external resistors provided in the hardware kit.
Enrollment
Figure 5: Enrollment
Configuring the biometric readers in
ACL800 BioManager
ACL800 BioManager is software for fingerprint management of
biometric readers, when used with third party access
controllers.
Main functions:
o
Fingerprint enrollment
It can be done by ANY Biometric reader in the network or by
desktop (USB) biometric reader
o
Fingerprint transfer
Finger templates can be sent to any reader in the network.
Different users can be sent to different biometric readers
o
Wiegand output Configuration
The Wiegand output of the Biometric reader can be
customized bitwise
P/N 1073512A• REV 00.00 • ISS 4JUL18