Description / Operation
ACL805SUW-BC is a Wiegand biometric keypad for access
control applications with backlit keys and programmable
Wiegand output. It offers storage up to 9500 fingerprints,
programmable Wiegand Output (24 to 80 bits) and selectable
PIN code length. Configuration of the readers and fingerprint
enrollment is done through ACL800 BioManager software.
When used with third party controllers, the connection between
the Biometric readers and the PC is done through ACL800FL-
CONV-W converter (RS485 to TCP/IP). Only one converter is
needed per system (one converter for 1, 2, 3...30, 31 biometric
readers).
The tamper switch output can trigger the alarm system, if an
attempt is made to open or remove the unit from the wall.
Specifications
Fingerprint capacity
Up to 9500 fingerprints
Technology
Biometry and keypad
Finger, access code, finger or/and access
Authentication
code
Fingerprints per user
1-10 fingerprints
Interface
Wiegand 24 to 80 bits; default: Wiegand 26bit
Protocol programming
By ACL800 BioManager software
Cable distance
50 m
Fingerprint Sensor
Capacitive
Type
© 2018 United Technologies Corporation.
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
1:1000 identification
970 msec, including feature extraction time
time
Fingerprint enrolment
On the reader or from the USB desktop reader
Panel Connection
Cable, 1 m
Green and Red LED
Externally controlled
Orange LED
Idle mode
Buzzer ON/OFF
Yes
Yes, by software setting
Backlight ON/OFF
Yes
Tamper
150 mA
Consumption
65
IP Rating
9 to 14 VDC
Power supply
Operating
-15 to +50°C, noncondensing
Temperature
100 x 94 x 30 mm
Dimensions
Moulded aluminium
Housing
Mounting
Figure 1: Mounting instructions
If the biometric reader is installed and used outdoor, the reader
MUST be fitted with a cover in order to protect the sensor from
direct rainfall. The operating temperature of the product is
between -15 to + 50ºC. If the reader is installed in an
environment where the temperature can drop below -10ºC
or/and if the sensor could only be exposed to direct sunlight, it
is strongly recommended to install the reader inside a third
party sealed wall mount box (fitted with additional heater if very
low temperature) to keep a constant sensor level performance.
We cannot guarantee the functionality of the product if
measures and advice before are not followed.
It is also strongly recommended to use double technology
biometric readers when use outdoor to offer first higher
security but also the possibility to use different readers
depending on users.
P/N 1073512A• REV 00.00 • ISS 4JUL18

Advertisement

loading

Summary of Contents for Interlogix ACL805SUW-BC

  • Page 1 Capacitive Type depending on users. P/N 1073512A• REV 00.00 • ISS 4JUL18 © 2018 United Technologies Corporation. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
  • Page 2: Wiring Description

    Wiring • The RS485 Line should be configured in the form of a daisy chain, NOT in a form of a star. Keep the stubs from the RS485 backbone as short as possible (not more than 5 Figure 2: Wiring meters) •...
  • Page 3: Add Reader

    Add Portal  Click on “Save” and the reader icon appears under • Right-click on “Portals” and select “Add Portal”. the selected portal • If the converter used for the biometric readers is RS485 to TCP/IP, then create a portal by adding the IP Address of the converter.
  • Page 4: Delete Reader

    Edit reader properties and click “Save” button. Check at event table if the configuration was successful. Delete reader  Right-click on the reader and select “Delete” reader 3. Right click on the fingertip and select enroll. 4. Place the finger on the Reader and fingertip will turn red, orange or green, with percentage of successful enrollment shown next to the fingertip.
  • Page 5: Deleting Fingerprints

     Click on “Delete User”. The User, together with its fingerprints will be deleted from both the software and the fingerprint readers In the event window, a line will appear indicating the number of fingerprints stored in the reader. Deleting all users from the biometric reader ...
  • Page 6: Uploading The Fingerprints To The Biometric Readers

    Uploading the fingerprints to the biometric Safety precautions readers Do not install the device in a place subject to direct sun light without protective cover.  Right click on the biometric reader Do not install the device and cabling close to a source of ...
  • Page 7: Regulatory Information

    RELATED PRODUCTS. For more information on warranty disclaimers and product safety information, please check www.firesecurityproducts.com/policy/product- warning/ or scan the following code: For contact information go to: www.interlogix.com Contact or www.firesecurityproducts.com information and To get translations for this and other product manuals manuals go to: www.firesecurityproducts.com...