Fetco ECO Series Programming Manual page 9

Table of Contents

Advertisement

54
Water Level
Sensitivity
55
Tank Temperature
56
Single Brewer
Model Number
Dual Brewer Model
Number
57
Reload Defaults
LO - HI
LO – 0 to 50 KΩ
HI – 50 to 130 KΩ
If water resistance (address
51) is greater than 25 KΩ,
set on HI to prevent
unwanted filling of tank.
180° - 206°F Displays current tank
temperature.
31 or 41
Must be set for the correct
model number of the brewer:
31 for CBS-2031ee,
32 or 42
32 for CBS-2032ee, etc.
0 - 1
Changes all settings to
default factory settings.
0 = Do not reload defaults
1 = Reload all defaults
If 1 is selected, you must
advance to the next address
for this change to take effect.
Does not change
address 56 – model number.