MULTIQUIP LS450 Operation Manual page 39

Concrete pump hatz 4h50 diesel engine
Hide thumbs Also See for LS450:
Table of Contents

Advertisement

1. Press the ON/OFF button on the radio (wireless)
remote control to turn on the power. Hold the RESET
switch up. The display will now show:
Screen 9
RADIO ADDRESS
NOW SCANNING
FOR NEW
TRANSMITTER
2. After 5 seconds, the display will show:
Screen 9
RADIO ADDRESS
COMMUNICATING
PRESS RESET TO
LEARN A NEW ONE
3. The hand-held remote control module is now ready
for use.
Remote Control Cable Operation (25 Feet)
The remote control cable (Figure 41) has the following
controls:
„ Pump ON/OFF — Starts and stops forward pumping.
„ Pump REV — Starts pumping in reverse direction.
REMOTE CONTROL CABLE UNIT
REMOTE CONTROL CABLE UNIT
PUMP REV
PUMP REV
PUMP ON/OFF
PUMP ON/OFF
Figure 41. Remote Control Cable
Connect the remote control cable (Figure 41) to the
receptacle labeled remote located on front of the digital
panel.
MAYCO LS450 CONCRETE PUMP • OPERATION MANUAL — REV. #2 (02/23/21) — PAGE 39
9
9
25 FT. CABLE
25 FT. CABLE
TO CONTROL BOX
TO CONTROL BOX
CONNECTOR
CONNECTOR
Before the remote control cable can be used, the pumping
volume rate must be set.
1. Start the pump as outlined in the Operation section
of this manual.
2. Place the pumping control switch in the LOCAL
position.
3. Using the momentary volume control switch, adjust
the pumping rate (volume) to the desired strokes per
minute.
4. Once the desired pumping rate has been achieved,
place the pumping control switch in the REMOTE
position.
OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mayco series