Before You Begin

The I-Series insert fireplaces must be installed in accordance with
these Instructions. Carefully read all the instructions in this manual
first. Consult the Local Gas Branch to determine the need for a permit
prior to starting the installation. It is the responsibility of the installer to
ensure this fireplace is installed in compliance with the manufacturers
instructions and all applicable codes.
Installations into a Factory Built Solid Fuel Burning Fireplace
This gas appliance has been tested and approved for installation into
any approved masonry or factory built solid fuel fireplace, in which
this gas insert will fit.
In the event that the vertical height of the factory built fireplace is less
than 20" you may remove some of the components such as the flue
baffle, flue damper or surround panels. These components can be
removed on the condition that:
1). The removal of such components in no way compromises the
structural integrity of the unit.
2). A label supplied with your insert is prominently affixed to the existing
fireplace. This label can be found included in the bag that contains
the back-up batteries for the insert.
REMOVE THIS
SECTION OF
This fireplace has been converted for use with a gas insert fireplace.
METAL FLOOR
The conversion of this fireplace voids its original certification and this
appliance can no longer be used as a solid fuel burning fireplace.
The bottom of the existing fireplace may be removed as long as it does
not compromise the structural integrity of the existing firplace and you
maintain a mandatory minimum 3/4" clearance between the bottom
of the insert and the bottom shell of the existing fireplace. This can be
achieved by using strips of noncombustible material or by using the
leveling bots on the insert.
REMOVE THIS
SECTION OF
METAL FLOOR
General
WARNING
LEVELING
3
BOLTS
"
MIN.
4
20
5

Advertisement