Bryant Legacy 569J 16-28 Installation Instructions Manual page 19

Table of Contents

Advertisement

NOMINAL
POWER
UNIT
NUMBER
SUPPLY
SIZE
OF
569J*
STAGES
V-Ph-Hz
208/230
16A
2
460
575
208/230
25A
2
460
575
NOMINAL
POWER
UNIT
NUMBER
SUPPLY
SIZE
OF
569J*
STAGES
V-Ph-Hz
208/230-3-60
16A
2
460-3-60
575-3-60
208/230-3-60
25A
2
460-3-60
575-3-60
NOTE(S):
a. See Legend and Notes for Tables 13 and14 on page 20.
NOMINAL
POWER
UNIT
NUMBER
SUPPLY
SIZE
OF
569J*
STAGES
V-Ph-Hz
208/230-3-60
16T
3
460-3-60
575-3-60
208/230-3-60
25T
3
460-3-60
575-3-60
208/230-3-60
28T
3
460-3-60
575-3-60
NOMINAL
POWER
UNIT
NUMBER
SUPPLY
SIZE
OF
569J*
STAGES
V-Ph-Hz
208/230-3-60
16T
3
460-3-60
575-3-60
208/230-3-60
25T
3
460-3-60
575-3-60
208/230-3-60
28T
3
460-3-60
575-3-60
NOTE(S):
a. See Legend and Notes for Tables 13 and14 on page 20.
Table 13 — 569J***A/B Unit Wire/Fuse Sizing Data
COMPRESSOR
VOLTAGE
RANGE
No. 1
Min
Max
RLA
LRA
187
253
25.0
164
414
506
12.2
100
518
633
9.0
78
187
253
30.1
225
414
506
16.7
114
518
633
12.2
80
COMPRESSOR
VOLTAGE
RANGE
No. 1
Min
Max
RLA
LRA
187
253
25.0
164
414
506
12.2
100
518
633
9.0
78
187
253
30.1
225
414
506
16.7
114
518
633
12.2
80
Table 14 — 569J***T/U Unit Wire/Fuse Sizing Data
COMPRESSOR
VOLTAGE
RANGE
No. 1
Min
Max
RLA
LRA
187
253
26.8
164
414
506
12.0
94
518
633
9.0
65
187
253
32.5
240
414
506
14.8
130
518
633
11.1
94
187
253
35.3
240
414
506
17.0
140
518
633
13.0
108
COMPRESSOR
VOLTAGE
RANGE
No. 1
Min
Max
RLA
LRA
187
253
26.8
164
414
506
12.0
94
518
633
9.0
65
187
253
32.5
240
414
506
14.8
130
518
633
11.1
94
187
253
35.3
240
414
506
17.0
140
518
633
13.0
108
No. 2
OFM
FLA
RLA
LRA
Qty
(ea)
25.0
164
3
1.5
12.2
100
3
0.8
9.0
78
3
0.7
30.1
225
4
1.5
16.7
114
4
0.8
12.2
80
4
0.7
No. 2
OFM
FLA
RLA
LRA
Qty
(ea)
25.0
164
3
1.5
12.2
100
3
0.8
9.0
78
3
0.7
30.1
225
4
1.5
16.7
114
4
0.8
12.2
80
4
0.7
No. 2
OFM
FLA
RLA
LRA
Qty
(ea)
25.0
164
3
1.5
12.2
100
3
0.8
9.9
78
3
0.7
28.2
240
4
1.5
14.7
130
4
0.8
11.3
94
4
0.7
48.4
245
4
1.5
19.0
125
4
0.8
16.0
100
4
0.7
No. 2
OFM
FLA
RLA
LRA
Qty
(ea)
25.0
164
3
1.5
12.2
100
3
0.8
9.9
78
3
0.7
28.2
240
4
1.5
14.7
130
4
0.8
11.3
94
4
0.7
48.4
245
4
1.5
19.0
125
4
0.8
16.0
100
4
0.7
19
a
NO C.O. OR POWERED C.O.
Power Supply
Disconnect Size
Fuse or
MCA
HACR
FLA
Breaker
60.8/60.8
80/80
63/63
29.9
40
31
22.4
30
23
73.7/73.7
100/100
76/76
40.8
50
42
30.3
40
31
WITH POWERED C.O.
Power Supply
Disconnect Size
Fuse or
MCA
HACR
FLA
Breaker
65.6/65.6
90/90
68/68
32.1
40
33
24.1
30
25
78.5/78.5
100/100
82/82
43
50
45
32
40
33
a
NO C.O. OR POWERED C.O.
Power Supply
Disconnect Size
Fuse or
MCA
HACR
FLA
Breaker
63/63
80/80
65/65
29.7
40
31
23.5
30
24
74.8/74.8
100/100
77/77
36.4
50
38
28
35
29
101.8/101.8
150/150
103/103
44
60
45
35.8
50
37
WITH POWERED C.O.
Power Supply
Disconnect Size
Fuse or
MCA
HACR
FLA
Breaker
67.8/67.8
90/90
70/70
31.9
40
33
25.2
30
26
79.6/79.6
100/100
82/82
38.6
50
40
29.7
40
31
106.6/106.6
150/150
109/109
46.2
60
48
37.5
50
39
LRA
337/337
206
162
462/462
236
168
LRA
342/342
208
164
467/467
238
170
LRA
337/337
200
149
492/492
268
196
497/497
273
216
LRA
342/342
202
151
497/497
270
198
502/502
275
218

Advertisement