Conducted Noise; Voltage Tolerance - Seagate IRONWOLF ST8000VN0004 Product Manual

Table of Contents

Advertisement

2.5.1.1
Typical current profiles
Figure 1.
Typical 5V and 12V startup and operation current profiles (10TB & 8TB)
2.5.2

Conducted noise

Input noise ripple is measured at the host system power supply across an equivalent 80-ohm resistive load on the +12 V line or an
equivalent 15-ohm resistive load on the +5V line.
• Using 12V power, the drive is expected to operate with a maximum of 120mV peak-to-peak square-wave injected noise at up to
10MHz.
• Using 5V power, the drive is expected to operate with a maximum of 100mV peak-to-peak square-wave injected noise at up to
10MHz.
Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write current.
Note
2.5.3

Voltage tolerance

Voltage tolerance (including noise):
5V ±5%
12V ± 10%
Seagate IronWolf Serial ATA Product Manual, Rev. B
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ironwolf st10000vn0004Ironwolf standard 512eSt10000vn0004