Download Print this page

Disassembly, Cleaning And Reassembly; Precaution For Disassembly And Inspection; Precaution For Reassembly; Piping Example - Yoshitake SY-17 Product Manual

Strainer

Advertisement

Excessive amount of foreign substances inside the product reduces filtration area and
hampers fluid flow. If the product is kept for such condition, the screen is damaged and
results in adverse effect on the piping system due to excessive pressure difference.

6.1 Precaution for disassembly and inspection

1. Completely discharge the pressure inside of the product, piping and equipment prior to disassembly
and inspection. When fluid is hot, cool down the product.
* Failure to follow this notice may result in scalds or injury due to the residual pressure.
1. After checking the pressure gauge to make certain there is no pressure inside the body [1], remove
the cap [2] and screen [3]. Clean up the screen [3] by compressed air or water.

6.2 Precaution for reassembly

1. Clean the gasket contact surfaces of both the body and the cap.
* Improper cleaning may cause fluid leakage at the gasket resulting in scalds or injury.
2. When installing caps and bolts, apply anti-galling agent to the threads.
* If you do not apply anti-galling agent, you may not be able to remove the cap and bolt.
1. After cleaning the gasket contact surfaces of both the body [1] and the cap [2], attach a new gasket
[4] to the cap [2], and then attach the cleaned screen [3] into the groove on the cap [2]. Install the
assembly (cap [2], gasket [4], and screen [3]) to the body [1].

6. Disassembly, Cleaning and Reassembly

7. Piping Example

Fig. 1
Fig. 3
Warning
Caution
5
Blow
Fig. 2
■EPDT-048a■

Advertisement

loading