Download Print this page

Yoshitake SY-17 Product Manual

Strainer

Advertisement

Quick Links

Thank you very much for choosing the Yoshitake's product. To ensure the correct and safe use of the product,
please read this manual before use. This manual shall be kept with care for future references.
The symbols used in this manual have the following meanings.
Warning
Caution
1. Specifications ···························································· 1
2. Dimensions ······························································ 1
3. Operation ································································· 2
4.1 Selection of nominal size ········································ 2
4.2 Selection of nominal pipe size ································· 2
4.3 Pressure Loss Chart ·············································· 3
5.1 Precaution for installation ······································· 4
5.2 Precaution for operation ········································· 4
6.1 Precaution for disassembly and inspection ················· 5
6.2 Precaution for reassembly ······································ 5
7. Piping Example ························································· 5
MODEL SY-17
STRAINER
PRODUCT MANUAL
This symbol indicates a potentially hazardous situation that, if not avoided,
could result in death or serious injury.
This symbol indicates a hazardous situation that, if not avoided, may result in
minor or moderate injury or may result in only property damage.

Table of Contents

.
■EPDT-056■

Advertisement

loading

Summary of Contents for Yoshitake SY-17

  • Page 1: Table Of Contents

    STRAINER PRODUCT MANUAL Thank you very much for choosing the Yoshitake’s product. To ensure the correct and safe use of the product, please read this manual before use. This manual shall be kept with care for future references. The symbols used in this manual have the following meanings.
  • Page 2: Specifications

    1. Specifications Application Steam, Air, Cold and hot water, Oil, Other non-dangerous fluids Max. pressure 2.0 MPa 100 °C (250 °C) * Max. temperature Body Cast stainless steel Material Screen Stainless steel Gasket PTFE * Perforations φ2.5 – 4P Screen Mesh Standard 80 mesh Connection...
  • Page 3: Operation

    3. Operation Parts Name Body Screen Gasket Dust, scale, and other foreign substances which flow into the inlet side of the strainer are removed by the screen [3]. 4. Nominal Size Selection To make the best use of the strainer and satisfy the operating requirements to the maximum, take notice of the following.
  • Page 4: Pressure Loss Chart

    4.3 Pressure Loss Chart [Screen] φ2.5 – 4P Mesh = 80 mesh ■EPDT-048a■...
  • Page 5: Maintenance

    5. Maintenance 5.1 Precaution for installation Caution 1. When installing, check the direction of the product so that the fluid flowing and the arrow marked on the product are in the same direction. * Setting the product in wrong directions prevents the product from performing as intended. 2.
  • Page 6: Disassembly, Cleaning And Reassembly

    6. Disassembly, Cleaning and Reassembly Excessive amount of foreign substances inside the product reduces filtration area and hampers fluid flow. If the product is kept for such condition, the screen is damaged and results in adverse effect on the piping system due to excessive pressure difference. 6.1 Precaution for disassembly and inspection Warning 1.
  • Page 7: Warranty Information

    ( e.g. in case of corrosion due to outdoor use). Fire, flood, earthquake, thunder and other natural disasters. Consumable parts such as O-ring, gasket, diaphragm and etc. Yoshitake is not liable for any damage or loss caused by malfunction or defect of the product. PDD-046f...