Dust, scale, and other foreign substances which flow into the inlet side of the strainer are removed by
the screen [3].
To make the best use of the strainer and satisfy the operating requirements to the maximum,
take notice of the following.

4.1 Selection of nominal size

Select a strainer of the same nominal size as that of the pipe (nominal size of piping = nominal size
of strainer). Note that using a strainer of a smaller nominal size increases the pressure loss of the
strainer and may result in the pressure fallen below the specified level at the inlet side of the
equipment.

4.2 Selection of nominal pipe size

When selecting an appropriate nominal pipe size, it is necessary to consider fluid type, maximum
flow rate, permissible pressure loss, costs of piping and equipment, etc.
If the nominal pipe size is smaller, the costs of piping and equipment decreases while the pressure
loss through the pipe increases to generate disturbances, possibly resulting in pipe wear, noise
and/or vibration. If the nominal pipe size is too large, not only the costs of piping and equipment but
also the thermal loss increases.
As a reference, the standard flow velocity is specified in the Japanese Industrial Standards (JIS) as
a guide to select an appropriate nominal pipe size. See the following table.
Fluid
Saturated steam
Superheated steam
Inlet of steam coil
Air
Water, Oil
* The above table is based on the requirements in JIS F 7101 "Shipbuilding - Pipes
of machinery - standard velocity of flow".

3. Operation

4. Nominal Size Selection

<<Standard flow velocity>>
Remarks
Auxiliary piping for vacuum or small-
diameter piping
Large-diameter piping
Piping diameter: approx. Φ75 –Φ250
Piping of high-grade material
0.3-0.7 MPa
Higher pressure: 1.0 MPa or more
Lower pressure
Extremely low pressure: 0.1 MPa or less
2
No.
Parts Name
1
Body
2
Cap
3
Screen
4
Gasket
Standard flow
velocity
15 m/s [10-20]
30 m/s [20-40]
40 m/s [30-50]
70 m/s [65-80]
30 m/s [25-30]
20 m/s [20-25]
15 m/s [5-15]
10 m/s [3-10]
2 m/s [2- 4]
■EPDT-048a■