Procedure for setting alarms to sensor

This paragraph explains steps for alarm settings on the selected sensor. By using these steps, you
can configure the contact outputs of the sensor or saving thermal image data.
Steps
[1] Selecting sensor
In [Sensor Selection] section, click one of the radio buttons of the sensor1-4 you want to set
alarms.
If IP Address has not been resistered, you cannot do the setup. Refer to [IP
Address](Page15).
[2] Parameter Setup
You can have 2 alarms per area.
Select the one of the following alarm conditions.
(1) Alarm off ... Alarm is disabled. All settings are not valid. (e.g. Value, Area, etc.)
(2) High ... When the temperature reading in the specified area is higher than the set value, the
contact output turns on.
(3) Low ... When the temperature reading in the specified area is lower than the set value, the
contact output turns on.
(4) Self Diagnostic Alarm ...When sensor detects an abnormal state on its internal memory or
The following is an example of Alarm 1 with High Alarm and Set Value of 150ºF.
I. Select High for High Alarm
[2]
[1]
[3]
Select the sensor for setting.
internal temperature, the contact output turns on. (Page 8 of Sensor
Manual)
II. Once High is selected, the
temperature set value can be
entered.
27
[4]
[5]
[6]
[7]