LAN settings of thermal image sensor
The setting for the thermal image sensor is performed through the
LAN in order to use sensors and connected PC properly.
When the sensor is used first time, the LAN settings of the sensor is required.

1. Initialization of thermal image sensor

As received from factory, no initialization is required since all
settings have been initialized.
In case of an error, etc. at the LAN environment settings, the set values can be reset to the default
values as shipped from factory by removing the mounting screw and then pushing the reset switch.
Turn the power on while pushing the initial switch for 1 second continuously. Resetting to the
default values becomes effective (The violet monitor lamp flashes 2 times.) By re-power-on,
the set values are reset to the default values at the shipment from factory. Usually do not push
the initial switch.
Remove the mounting
screw.
[Factory default settings]
Items
IP address
Subnet mask
Gateway address
Sensor number
UDP port address
Emissivity
Alarm setting
*1 If you use UDP port on your PC and the UDP port address that you are using is
overlapping with this address, change the UDP address that you are using.
[MEMO]
Reset switch (behind the screw)
192.168.1.254
255.255.255.0
0.0.0.0 (Invalidation)
1
50828 (fixed)
1.00 (for all pixels)
Alarm disabled
9
Reset switch