3.
The programming LED flashes once to show that the current
value is off.
4.
Press the programming button twice.
5.
The programming LED flashes twice showing that the new
value has been stored. The detector returns to normal
operation.
Resetting options
To reset the detector to the default settings:
1.
Remove the power from the detector.
2.
Press and hold the programming button (see Figure 16,
item 2).
3.
Apply the power to the detector.
4.
After the programming LED flashes, release the programming
button.
You can reset the detector either before installation, with a PP3
battery, or by applying 12 V to the unit on site.
Walk test
In walk test mode, the blue detection LED option is set to ON, and
the pulse count option is set to 1. The detection LED lights each
time DI601 / DDI602 detects your presence.
To enter the walk test mode, press the programming button once.
The detection LED lights and pulse count 1 is automatically
selected. The unit can then be aligned. The detection LED lights on
DI601 / DDI602 every time detection takes place.
The test mode ends automatically five minutes after last detection.
Alternatively, remove and then reapply the power to cancel the
walk test mode.
Note:
When you conduct a walk test, make sure that the front
cover is in place. Do not conduct walk tests with the cover
removed.
The range of the detector increases without the protective front
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Use Table 3 on page 6 to adjust the range
as necessary. Pan and tilt the lens module over the field of view to
obtain the correct coverage area.
Accessories
GE Security can provide a handheld walk tester DI601-WT to aid
installations.

Specifications

Detection range
Programmable: 10 m / 30 ft., 20 m / 66 ft., or
30 m / 98 ft.
Coverage
10 to 70° detection angle, 30 x 24 m /
98 x 79 ft. coverage max.
Adjustment
180° pan, 90° tilt
Fresnel lens
28 zones for each detection element, which
can be masked with the curtain sliders
Customized optics
Double silicon shielded quad element
eliminates 50,000 lux of white light
P/N 1069153 / 1069154 • REV 00.09 • ISS 18DEC09
Top red: Programming LED
LEDs
Red: Programming LED
Red: PIR active
Green: Microwave active
Blue: Detector alarm
Infrared: Walk tester communication
Microwave module
Operating frequency (country specific)
DDI602-F1
10.525 GHz
DDI602-F2
10.587 GHz
DDI602-F3
9.9 GHz
Outputs
Silent, solid state, magnetically immune.
Triggering selectable by microwave OR
PIR, or by microwave AND PIR.
N/O
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
N/C
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
Power input
9 to 15 V
7 mA (12 V nominal)
Current
11 mA (12 V nominal)
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with nonvolatile
memory
Walk test
Output test mode with LED indication. Option
to disable LEDs.
Operating temperature
−20 to +65°C / −4 to 149°F
Housing
High impact ABS plastic with HDPE cover,
UV stabilized
Dimensions, W x H x D
147 x 187 x 140 mm / 5.79 x 7.36 x 5.51 in.
306 g net, 532 g gross / 10.79 oz net,
Weight
18.77 oz gross
323 g net, 549 g gross / 11.39 oz net,
19.37 oz gross
Mounting height
Variable up to 6 m / 20 ft.
Optimum height 3 m / 10 ft. for full range
Cable < 200 m / 656 ft.
Utilising all three outputs (including tamper) —
eight-core 7/0.2 mm² / 24 AWG
Cable < 500 m / 1640 ft.
Utilising all three outputs (including tamper) —
eight-core 16/0.2 mm² / 20 AWG

Regulatory information

Certification
INCERT (pending)
EN (pending)
Grade 2 Class IV
Environmental class
Minimum IP55 (IP65 pending)
European Union
1999/5/EC (R&TTE directive): Hereby, GE Security
directives
declares that this device is in compliance with the
essential requirements and other relevant
provisions of Directive 1999/5/EC.