Mounting Options - ADTRAN NetVanta 644 Hardware Installation Manual

Hide thumbs Also See for NetVanta 644:
Table of Contents

Advertisement

NetVanta 640 Series Hardware Installation Guide

Mounting Options

The NetVanta 644 can be installed in rackmount, wallmount, or tabletop configurations. The following sections
provide step-by-step instructions for rack mounting and wall mounting.
When installing and operating the NetVanta 644, a minimum of 1-inch clearance should
be maintained on all sides of the unit. The airflow inlets and outlets should be
unobstructed at all times.
Rack Mounting the NetVanta
The NetVanta is a 1U-high, rack-mountable unit that can be installed into a 19-inch equipment rack. The
following steps guide you in mounting the NetVanta into a rack.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient temperature. Therefore,
consideration should be given to installing the equipment in an environment compatible
with the maximum ambient temperature specified by the manufacturer.
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
Be careful not to compromise the stability of the equipment mounting rack when
installing this product.
Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading the circuit might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
Reliable grounding of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the
branch circuit (e.g., use of power strips).
Step
1
Attach the rackmount brackets using the supplied screws.
2
To allow proper grounding, scrape the paint from the rack around the mounting holes where the
NetVanta will be positioned.
3
Position the NetVanta in a stationary equipment rack. This unit occupies 1U of space.
4
Have an assistant hold the unit in position as you install two mounting bolts through the unit's
brackets and into the equipment rack using a #2 Phillips-head screwdriver.
5
Apply power to the unit (refer to
61700144G1-34A
Instructions for Rack Mounting the NetVanta
Supplying Power to the Unit on page
Copyright © 2011 ADTRAN, Inc.
Action
Unit Installation
22).
19